Anaerobic Digester Heat Requirement and Cool-down

Heat to warm the sludge feed and to make up losses through wall, floor and roof of a cylindrical digester, and the temperature drop if heating stops for a day.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Insulated 15 m digester, mild climateCold climate 25 m, exposed wall

Accepted: 86.4 to 8,640,000 kg/d
Accepted: 3 to 4.5 kJ/(kg·K)
Accepted: 10 to 60 °C
Accepted: 0 to 40 °C
Accepted: 2 to 60 m
Accepted: 1 to 30 m
Accepted: 1 to 40 m
Accepted: 0.05 to 10 W/(m²·K)
Accepted: -30 to 40 °C
Accepted: 0.05 to 10 W/(m²·K)
Accepted: -20 to 40 °C
Accepted: 0.05 to 10 W/(m²·K)
Accepted: -40 to 40 °C
Accepted: 950 to 1,200 kg/m³

Results

The floor is a cone of the given centre depth; the roof is taken as flat.

Sludge heating36.944kW
Wall loss5.0894kW
Floor loss5.4867kW
Roof loss4.5239kW
Heat exchanger duty52.044kW
Daily heat4.4966GJ
Digester volume1,531.5m³
Temperature drop in 24 h without heat0.69906K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Insulated 15 m digester, mild climate. The inputs, in the units selected above:

InputValue
Sludge feed40,000 kg/d
Sludge specific heat4.2000 kJ/(kg·K)
Digester temperature37.000 °C
Incoming sludge temperature18.000 °C
Diameter15.000 m
Side water depth8.0000 m
Depth at the centre (cone floor)10.000 m
Wall coefficient0.50000 W/(m²·K)
Earth or air next to the wall10.000 °C
Floor coefficient1.2000 W/(m²·K)
Earth below the floor12.000 °C
Roof coefficient0.80000 W/(m²·K)
Air above the roof5.0000 °C
Sludge density1,000.0 kg/m³

Applying the formula below gives:

ResultValue
Sludge heating36.944 kW
Wall loss5.0894 kW
Floor loss5.4867 kW
Roof loss4.5239 kW
Heat exchanger duty52.044 kW
Daily heat4.4966 GJ
Digester volume1,531.5 m³
Temperature drop in 24 h without heat0.69906 K

Open this example in the calculator and change any input.

Formula

\(q_s = \dot mc_p(T_d - T_s), \quad q = UA\,\Delta T\ \text{(wall, floor, roof)}, \quad \Delta T_{24h} = \frac{Q_d}{\rho Vc_p}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Sludge feed kg/s
\(c_p\) Sludge specific heat J/(kg·K)
\(T_d\) Digester temperature K
\(T_s\) Incoming sludge temperature K
\(D\) Diameter m
\(h_s\) Side water depth m
\(h_m\) Depth at the centre (cone floor) m
\(U_w\) Wall coefficient W/(m²·K)
\(T_{ew}\) Earth or air next to the wall K
\(U_f\) Floor coefficient W/(m²·K)
\(T_{ef}\) Earth below the floor K
\(U_r\) Roof coefficient W/(m²·K)
\(T_a\) Air above the roof K
\(\rho\) Sludge density kg/m³
\(q_s\) Sludge heating W
\(q_w\) Wall loss W
\(q_f\) Floor loss W
\(q_r\) Roof loss W
\(q\) Heat exchanger duty W
\(Q_d\) Daily heat J
\(V\) Digester volume m³
\(\Delta T\) Temperature drop in 24 h without heat K

Method and standards

Digester heat balance.

Where it is used

  • Heat exchanger and boiler sizing for digesters.
  • Winter operation checks.

Common mistakes

  • Leaving out the feed heating.
  • Using air temperature against buried walls.

Assumptions and limits

  • Steady losses; radiation included in U.

Questions and answers

Why is the sludge heating the largest part?

Thickened sludge is mostly water; raising 90 t/d by 25 K needs about 95 GJ a day, twice the conduction losses.

What do the defaults represent?

An illustrative case: Insulated 15 m digester, mild climate. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 13-9, eq. 13-17 and Example 13-7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.