FireCADCalc

Biological Sludge Production from Yield and Decay

Biomass produced in an activated sludge process from flow, BOD removed, yield coefficient, decay coefficient and sludge age, as volatile and total solids.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10-day sludge ageExtended aeration 25 days

Your design value; often 0.4–0.8.

Results

Add inert influent solids to the total for the sludge handling load. Y is per kg BOD₅ removed; no cell-debris term is included, so P_x is lower than a full Metcalf & Eddy VSS production that adds f_d k_d X θ_c debris.

Observed yield0.37500
Biomass produced (VSS)217.50kg/d
Total solids produced271.87kg/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10-day sludge age. The inputs, in the units selected above:

InputValue
Wastewater flow2,000.0 m³/d
Influent BOD₅300.00 mg/L
Effluent soluble BOD₅10.000 mg/L
Yield (kg VSS per kg BOD₅)0.60000 -
Endogenous decay coefficient0.060000 1/d
Sludge age (SRT)10.000 d
Volatile share of the solids80.000 %

Applying the formula below gives:

ResultValue
Observed yield0.37500
Biomass produced (VSS)217.50 kg/d
Total solids produced271.87 kg/d

Open this example in the calculator and change any input.

Formula

\(Y_{obs} = \frac{Y}{1 + k_d\theta_c}, \quad P_x = Y_{obs}\,Q(S_0 - S)\)

Variables

Symbol Meaning SI unit
\(Q\) Wastewater flow m³/s
\(S_0\) Influent BOD₅ kg/m³
\(S\) Effluent soluble BOD₅ kg/m³
\(Y\) Yield (kg VSS per kg BOD₅) -
\(k_d\) Endogenous decay coefficient 1/s
\(\theta_c\) Sludge age (SRT) s
\(VSS/TSS\) Volatile share of the solids -
\(Y_{obs}\) Observed yield -
\(P_x\) Biomass produced (VSS) kg/s
\(P_{TSS}\) Total solids produced kg/s

Method and standards

Biomass balance.

Where it is used

  • ETP sludge handling design.
  • Dewatering equipment sizing.

Common mistakes

  • Units of k_d.
  • Total BOD for soluble.

Assumptions and limits

  • Steady state, complete mix.
  • The yield Y is on a BOD₅ basis (kg VSS per kg BOD₅ removed); yields quoted per kg bCOD are lower and must not be mixed in.
  • Active biomass only: the cell-debris (endogenous residue) term and inert influent VSS are not included, so P_x is lower than a full Metcalf & Eddy VSS production.
  • If the effluent BOD exceeds the influent, the removal is taken as zero and the page warns.

References

  • P_x = Y Q (S₀ − S)/(1 + k_d θ_c) (Metcalf & Eddy)

Questions and answers

2000 m³/d, 290 mg/L removed, Y 0.6, k_d 0.06/d, SRT 10 d?

Observed yield 0.375: about 217 kg VSS a day.

Longer sludge age?

More decay: less sludge but more oxygen.

Industrial effluent?

Yields vary widely; measure if you can.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators