Worked example
Example: 4000 m3/d, 180 mg/L, 25 m x 2 m, R 1.5, 20 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wastewater flow | 4,000.0 m³/d |
| Settled influent BOD | 180.00 mg/L |
| Filter diameter | 25.000 m |
| Media depth | 2.0000 m |
| Recirculation ratio | 1.5000 - |
| Wastewater temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| BOD load | 720.00 kg/d |
| Media volume | 981.75 m³ |
| Recirculation factor | 1.8904 |
| Efficiency at 20 °C | 78.367 % |
| Efficiency at T | 78.367 % |
| Effluent BOD | 38.940 mg/L |
Open this example in the calculator and change any input.
Formula
\(E = \frac{100}{1 + 0.4432\sqrt{\dfrac{W}{VF}}}, \quad F = \frac{1 + R}{(1 + R/10)^2}, \quad E_T = \min\left(E_{20}\,1.035^{T - 20},\ 0.99\right)\ \ (W\ \mathrm{kg/d},\ V\ \mathrm{m^3})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Wastewater flow | m³/s |
| \(BOD\) | Settled influent BOD | kg/m³ |
| \(D\) | Filter diameter | m |
| \(H\) | Media depth | m |
| \(R\) | Recirculation ratio | - |
| \(T\) | Wastewater temperature | K |
| \(W\) | BOD load | kg/s |
| \(V\) | Media volume | m³ |
| \(F\) | Recirculation factor | - |
| \(E_{20}\) | Efficiency at 20 °C | - |
| \(E_T\) | Efficiency at T | - |
| \(BOD_e\) | Effluent BOD | kg/m³ |
Method and standards
NRC first-stage equation.
Where it is used
- Upgrading and checking existing filters.
- Roughing filters before activated sludge.
Common mistakes
- Using raw instead of settled BOD.
- Applying it to high-rate plastic media.
Assumptions and limits
The temperature-corrected efficiency is capped at 99 % (the page says when the cap applies); the NRC equation was not fitted to removals that high.
Single stage; domestic-type wastewater.
References
- Metcalf & Eddy
- Wastewater Engineering: Treatment and Resource Recovery
- 5th ed. (McGraw-Hill, 2014)
- ch. 9 (NRC equations for stone-media trickling filters, SI form, θ = 1.035)
Questions and answers
What does recirculation do?
It dilutes the feed and wets the media better; the NRC factor F rises from 1 with no recirculation to 2.75 at R = 10.
Why does temperature matter?
Biological rates fall in cold weather: about 3.5 % per °C.
What do the defaults give?
4,000 m³/d at 180 mg/L on a 25 m × 2 m filter with R 1.5: about 78 % removal.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.