Dissolved Air Flotation: Air-to-Solids Ratio

Air-to-solids ratio of a dissolved air flotation unit with pressurised recycle from air solubility, pressure, recycle and feed solids, and recycle needed.

Distillery and ethanolRefinery and petrochemicalPulp and paperFood, dairy and textile

Inputs

Examples: 100 m³/h at 3,000 mg/L, 30 m³/h recycle at 4.5 bar(a)Paper-mill white water 400 mg/L, 6 bar

Results

A/S = 0.0030 is outside the typical design range 0.005–0.06: check the recycle, pressure and solids.

A/S = 1.3s_a(fP − 1)R/(QS_a), P in atmospheres, 1.3 mg of air per mL. Typical design A/S is 0.005–0.06; air solubility is 29.2, 22.8, 18.7 and 15.7 mL/L at 0, 10, 20 and 30 °C.

Air-to-solids ratio (mL/mg × 1.3)0.002967
Recycle for the target A/S202.21m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 m³/h at 3,000 mg/L, 30 m³/h recycle at 4.5 bar(a). The inputs, in the units selected above:

InputValue
Air solubility at the temperature (mL/L)18.700 -
Fraction of saturation achieved50.000 %
Saturator pressure (absolute)4.5000 bar
Pressurised recycle flow30.000 m³/h
Feed flow100.00 m³/h
Feed suspended solids (mg/L)3,000.0 -
Target air-to-solids ratio0.020000 -

Applying the formula below gives:

ResultValue
Air-to-solids ratio (mL/mg × 1.3)0.002967
Recycle for the target A/S202.21 m³/h

Open this example in the calculator and change any input.

Formula

\(\frac AS = \frac{1.3s_a(fP - 1)R}{QS_a}\)

Variables

Symbol Meaning SI unit
\(s_a\) Air solubility at the temperature (mL/L) -
\(f\) Fraction of saturation achieved -
\(P\) Saturator pressure (absolute) Pa
\(R\) Pressurised recycle flow m³/s
\(Q\) Feed flow m³/s
\(S_a\) Feed suspended solids (mg/L) -
\((A/S)_t\) Target air-to-solids ratio -
\(A/S\) Air-to-solids ratio (mL/mg × 1.3) -
\(R_t\) Recycle for the target A/S m³/s

Method and standards

Air-to-solids ratio.

Where it is used

  • Oily effluent and paper-mill fibre recovery.
  • Sludge thickening.

Common mistakes

  • Using gauge pressure.
  • Ignoring temperature effect on solubility.

Assumptions and limits

  • Pressurised recycle system.
  • An A/S outside the typical 0.005–0.06 is flagged.

References

  • Air-to-solids relation for pressurised recycle (Metcalf & Eddy, Wastewater Engineering, 5th ed. (McGraw-Hill, 2014), ch. 5 and 14)

Questions and answers

What does A/S control?

Enough released air bubbles must attach to the solids to float them; too little leaves solids behind.

Why recycle instead of pressurising the feed?

Pressurising clear recycle avoids shearing fragile floc and blocking the saturator.

What do the defaults represent?

100 m³/h of oily or sludge feed at 3,000 mg/L with 30 m³/h recycle saturated at 4.5 bar(a).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.