One method, stated on every page
Each calculator shows its formula, explains every symbol, names the standard or textbook it follows, and lists its assumptions and limits. Nothing is hidden behind the Calculate button: the page you see is the whole method.
SI inside, your units outside
All calculations run in base SI units (metres, kilograms, seconds, kelvin, pascals). Your units are converted only at the inputs and the results, with conversion factors from NIST Special Publication 811. Gauge pressures are converted to absolute before any property is looked up.
Our own steam tables and gas properties
Water and steam properties come from FireCAD's own implementation of the IAPWS-IF97 industrial formulation, with the IAPWS 2008 viscosity and 2011 thermal conductivity releases. It reproduces the verification tables published by IAPWS and is cross-checked against an independent implementation at thousands of points. Flue gas properties use NIST Shomate heat capacities and published viscosity and conductivity methods.
Independent expected values
Every calculator carries worked examples whose answers are computed separately, in a different program written from the textbook formulas, with steam and water from an independent IAPWS library. They are never copied from the calculator's own output. A calculator that does not reproduce them, to a stated tolerance, is not published.
Tested on every release
Each release runs more than a thousand automated checks: every example of every calculator, the IAPWS verification values, unit conversions, and checks that no calculator fails on zero, negative or nonsense inputs. The site is updated only when all of them pass.
Defaults and margins
Where a design margin or efficiency is needed, it is an input you can change. Defaults come from FireCAD design practice and are labelled as such; your specification always takes precedence. Values that depend on a code table, chart or maker's data are left as inputs rather than guessed.
Limits
Results are engineering estimates for design and checking. For pressure parts, safety devices and anything a code or an inspecting authority governs, the code edition in force and that authority decide.
Found a mistake?
Write to us through firecad.com with the calculator and the inputs. We correct the calculator, add your case to its tests and record the change.