Instrumentation and Control
Flow elements, control valves, transmitters, thermowells and control loops.
Orifice plates, venturis, nozzles, compensation and flow conversions.
- DP Flow Square-Root Extraction and Low-Flow Cut-Off
- Flow Nozzle (ISA 1932) Liquid Flow
- Flowmeter K-Factor and Meter Factor from a Proving Run
- Flowmeter Pulse Output and Totaliser Scaling (K-Factor)
- Gas DP Flowmeter Pressure and Temperature Compensation
Valve Cv and Kv, sizing for liquids, gases and steam, noise and cavitation.
- Control Valve Actuator Thrust and Spring Check
- Control Valve Authority
- Control Valve Cavitation Index (σ)
- Control Valve Characteristic, Authority and Installed Flow
- Control Valve Characteristic: Flow at an Opening
Transmitter ranges, hydrostatic and differential-pressure level, wet legs.
- Bubbler (Dip-Tube) Level and Density Measurement
- Capacitance Level Probe: Capacitance and Span
- Displacer Level: Buoyancy Force and Range
- DP Level Transmitter Range (LRV, URV, Wet Leg)
- Drum Level from DP Transmitter (Density Compensation)
Thermocouples, RTDs, thermowell checks and conversions.
- Infrared Thermometer Emissivity Correction
- Probe in Hot Gas: Radiation Error of a Thermocouple or Lance
- Pt100 / Pt1000 RTD Resistance–Temperature Calculator
- RTD Lead Wire Error: 2-Wire, 3-Wire and 4-Wire
- RTD Self-Heating Error
PID tuning, loop scaling, 4–20 mA and signal conversions.
- 4–20 mA Loop Load Resistance and Cable Length
- 4–20 mA Signal Scaling Calculator
- Cohen–Coon PI and PID Tuning
- Feedforward Controller: Gain, Lead–Lag and Dead Time
- Lambda (IMC) Tuning for PI Controllers
pH, conductivity, oxygen and gas detection, and sample systems.
- Analyser Sample Line Transport Lag
- Calibration Gas Blending by Partial Pressure
- Chromatography: Theoretical Plates, HETP and Resolution
- Conductivity Cell Constant and Measured Conductivity
- Conductivity Temperature Compensation to 25 °C
Vibration conversions, machine fault frequencies, balancing, sound levels and noise dose.
- A-Weighted Sound Level from Octave-Band Levels
- Adding and Subtracting Sound Levels (dB)
- Day–Night and Day–Evening–Night Noise Levels (Ldn, Lden)
- Machine Fault Frequencies: Gear Mesh, Belt and Blade Pass
- Noise Barrier Attenuation (Maekawa Fresnel Number)
Decibels, ADC resolution, sampling, accuracy, calibration and repeatability.
- ADC and DAC Resolution, LSB and Ideal SNR
- Calibration: Error, Hysteresis and Pass/Fail at Five Points
- Dead-Weight Tester Pressure with Local Gravity and Air Buoyancy
- Decibel Calculator: Power, Voltage and Current Ratios
- Flowmeter Turndown and Accuracy over the Range