FireCADCalc

Infrared Thermometer Emissivity Correction

True surface temperature from an infrared thermometer reading taken at one emissivity setting, for the real emissivity and the reflected background temperature.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Shows 150 °C at 0.95, steel of 0.3, 30 °C backgroundPainted pipe 0.9 set at 0.95: shows 80 °C, 25 °C surroundingsFurnace wall: 900 °C shown at 1.0, real 0.85, hot surroundings 700 °C

Results

Total-radiation (Stefan–Boltzmann) model; real instruments work in a band (8–14 µm), so this is an estimate. Better: set the right emissivity, or use tape of known emissivity.

True surface temperature263.96°C
Correction (true − shown)113.96K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Shows 150 °C at 0.95, steel of 0.3, 30 °C background. The inputs, in the units selected above:

InputValue
Temperature shown by the instrument150.00 °C
Emissivity set in the instrument0.95000 -
Real emissivity of the surface0.30000 -
Reflected (background) temperature30.000 °C

Applying the formula below gives:

ResultValue
True surface temperature263.96 °C
Correction (true − shown)113.96 K

Open this example in the calculator and change any input.

Formula

\(\varepsilon_{set} T_{ind}^4 + (1 - \varepsilon_{set}) T_r^4 = \varepsilon T^4 + (1 - \varepsilon) T_r^4\)

Variables

Symbol Meaning SI unit
\(T_{ind}\) Temperature shown by the instrument K
\(\varepsilon_{set}\) Emissivity set in the instrument -
\(\varepsilon\) Real emissivity of the surface -
\(T_{refl}\) Reflected (background) temperature K
\(T\) True surface temperature K
\(\Delta T\) Correction (true − shown) K

Method and standards

Radiance balance, broadband.

Where it is used

  • Thermography surveys of insulation and steam traps.
  • Spot checks of bearings and motors.

Common mistakes

  • Default 0.95 on bare metal.
  • Ignoring reflections.

Assumptions and limits

  • Grey, opaque surface; broadband model.

References

  • Stefan–Boltzmann law with reflected radiation
  • εT⁴ + (1 − ε)T_r⁴

Questions and answers

An IR gun set to 0.95 shows 150 °C on bright steel of emissivity 0.3: true temperature?

Much higher, around 260 °C with a 30 °C background: low emissivity surfaces read far low.

Why include the background?

A shiny surface reflects its surroundings, which the instrument also sees.

How to measure shiny metal?

Paint a spot or use tape of known emissivity.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.