FireCADCalc

Radiation Heat Transfer Between Surfaces

Net radiant heat exchange by the Stefan–Boltzmann law for a body in large surroundings or two large parallel plates, with the radiation coefficient.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoilerBurner and furnace

Inputs

Examples: Hot casing 300 °C, 10 m², eps 0.8, room 30 °CParallel plates 800 °C and 200 °C, eps 0.85 and 0.6, 1 m²Aluminium cladding 60 °C, eps 0.1, 50 m², 25 °C

Results

Grey, diffuse surfaces and a transparent gap (no absorbing gas such as flue gas between them).

Net heat exchange45.121kW
Heat flux4.5121kW/m²
Radiation heat transfer coefficient16.712W/(m²·K)
Effective emissivity80.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hot casing 300 °C, 10 m², eps 0.8, room 30 °C. The inputs, in the units selected above:

InputValue
ArrangementSmall body in large surroundings
Surface area (of the body, or of one plate)10.000 m²
Hot surface temperature300.00 °C
Cold surface or surroundings temperature30.000 °C
Emissivity of the hot surface80.000 %
Emissivity of the cold plate (plates only)80.000 %

Applying the formula below gives:

ResultValue
Net heat exchange45.121 kW
Heat flux4.5121 kW/m²
Radiation heat transfer coefficient16.712 W/(m²·K)
Effective emissivity80.000 %

Open this example in the calculator and change any input.

Formula

\(\dot Q = F_\varepsilon\,\sigma\,A\,(T_1^4 - T_2^4) \qquad F_\varepsilon = \varepsilon_1 \text{ (small body)} \quad F_\varepsilon = \frac{1}{1/\varepsilon_1 + 1/\varepsilon_2 - 1} \text{ (plates)} \qquad h_r = \frac{q}{T_1 - T_2}\)

Variables

Symbol Meaning SI unit
\(\text{case}\) arrangement –
\(A\) area m²
\(T_1\) hot surface temperature K
\(T_2\) cold surface temperature K
\(\varepsilon_1\) hot emissivity –
\(\varepsilon_2\) cold emissivity –
\(\dot Q\) net heat exchange W
\(q\) heat flux W/m²
\(h_r\) radiation coefficient W/(m²·K)
\(F_\varepsilon\) effective emissivity –
\(\sigma\) Stefan–Boltzmann constant W/(m²·K⁴)

Method and standards

Stefan–Boltzmann law for grey diffuse surfaces in the two limiting geometries.

Where it is used

  • Casing and duct heat loss.
  • Furnace and heater wall checks.
  • Personnel protection shields.

Common mistakes

  • Using °C instead of K.
  • Using emissivity of bright metal for oxidised surfaces.
  • Ignoring absorbing flue gas between surfaces.

Assumptions and limits

  • Grey, diffuse surfaces; non-absorbing medium.

References

  • Stefan–Boltzmann law (CODATA 2018 σ)

Questions and answers

How much does a 10 m² casing at 300 °C radiate to a 30 °C room?

45.1 kW with emissivity 0.8 (4.5 kW/m², radiation coefficient 16.7 W/m²K).

Why use parallel plates?

For two large facing surfaces, such as a furnace wall and its casing, both emissivities count.

Does it include convection?

No; add convection separately or use the surface heat loss calculator.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.