Worked example
Example: Furnace wall: 230 mm firebrick, 115 mm insulating brick, 6 mm steel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inside fluid temperature | 900.00 °C |
| Outside fluid temperature | 30.000 °C |
| Inside surface coefficient | 50.000 W/(m²·K) |
| Outside surface coefficient (convection + radiation) | 10.000 W/(m²·K) |
| Layer 1 thickness | 230.00 mm |
| Layer 1 conductivity | 1.2000 W/(m·K) |
| Layer 2 thickness | 115.00 mm |
| Layer 2 conductivity | 0.25000 W/(m·K) |
| Layer 3 thickness | 6.0000 mm |
| Layer 3 conductivity | 45.000 W/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Overall coefficient | 1.2957 W/(m²·K) |
| Heat flux | 1,127.2 W/m² |
| Inside surface temperature | 877.46 °C |
| Interface 1–2 temperature | 661.40 °C |
| Interface 2–3 temperature | 142.87 °C |
| Outside surface temperature | 142.72 °C |
Open this example in the calculator and change any input.
Formula
\(q'' = \frac{T_{in} - T_{out}}{\dfrac{1}{h_i} + \sum \dfrac{L_j}{k_j} + \dfrac{1}{h_o}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{in}\) | Inside fluid temperature | K |
| \(T_{out}\) | Outside fluid temperature | K |
| \(h_i\) | Inside surface coefficient | W/(m²·K) |
| \(h_o\) | Outside surface coefficient (convection + radiation) | W/(m²·K) |
| \(L_1\) | Layer 1 thickness | m |
| \(k_1\) | Layer 1 conductivity | W/(m·K) |
| \(L_2\) | Layer 2 thickness | m |
| \(k_2\) | Layer 2 conductivity | W/(m·K) |
| \(L_3\) | Layer 3 thickness | m |
| \(k_3\) | Layer 3 conductivity | W/(m·K) |
| \(U\) | Overall coefficient | W/(m²·K) |
| \(q''\) | Heat flux | W/m² |
| \(T_{s,i}\) | Inside surface temperature | K |
| \(T_{12}\) | Interface 1–2 temperature | K |
| \(T_{23}\) | Interface 2–3 temperature | K |
| \(T_{s,o}\) | Outside surface temperature | K |
Method and standards
Steady one-dimensional conduction.
Where it is used
- Furnaces, ovens and cold rooms.
- Heat transfer examinations.
Common mistakes
- Using room-temperature conductivities.
- Ignoring contact resistance.
Assumptions and limits
- Plane wall, steady state.
- Constant conductivities: enter each at its layer's mean temperature and repeat if the interface temperatures move a lot (refractory conductivity varies strongly with temperature).
- A fixed outside coefficient h_o including radiation: at hot surfaces radiation makes h_o depend on the surface temperature, so check h_o against the T_s,o found and repeat.
References
- Fourier conduction with resistances in series (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, ch. 3)
Questions and answers
Firebrick, insulating brick and steel at 900 °C inside?
U about 1.3 W/(m²·K), about 1.1 kW/m², steel shell near 143 °C.
Why check interface temperatures?
Insulating brick and fibre have upper limits; the hot face layer protects them.
What sets the outside coefficient?
Convection and radiation together, about 10 W/(m²·K) in still air.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.