Overall Heat Transfer Coefficient (U) of a Tube

Overall heat transfer coefficient of a tube from the outside and inside film coefficients, wall conduction and fouling, on the outside and inside area.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoilerEconomiser and air preheater

Inputs

Examples: Economiser tube: gas 60, water 5000 W/(m²K), 51 x 4.5 mm steelCondenser tube: steam 10000, water 7000, 19.05 x 0.71 mm SSAir heater tube: gas 40, air 35, 63.5 x 2.6 mm

Results

U on the outside area56.686W/(m²·K)
U on the inside area68.833W/(m²·K)
Total resistance (outside area basis)0.017641m²·K/W
Share of the wall in the resistance0.62367%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Economiser tube: gas 60, water 5000 W/(m²K), 51 x 4.5 mm steel. The inputs, in the units selected above:

InputValue
Outside film coefficient60.000 W/(m²·K)
Inside film coefficient5,000.0 W/(m²·K)
Tube outside diameter51.000 mm
Tube inside diameter42.000 mm
Wall thermal conductivity45.000 W/(m·K)
Outside fouling resistance (on the outside area)5.0000e-04 m²·K/W
Inside fouling resistance (on the inside area)1.0000e-04 m²·K/W

Applying the formula below gives:

ResultValue
U on the outside area56.686 W/(m²·K)
U on the inside area68.833 W/(m²·K)
Total resistance (outside area basis)0.017641 m²·K/W
Share of the wall in the resistance0.62367 %

Open this example in the calculator and change any input.

Formula

\(\frac{1}{U_o} = \frac{1}{h_o} + R_{fo} + \frac{d_o \ln(d_o/d_i)}{2 k_w} + R_{fi}\frac{d_o}{d_i} + \frac{d_o}{d_i\,h_i} \qquad U_i = U_o\,\frac{d_o}{d_i} \qquad R_o = \frac{1}{U_o}\)

Variables

Symbol Meaning SI unit
\(h_o\) outside film coefficient W/(m²·K)
\(h_i\) inside film coefficient W/(m²·K)
\(d_o\) outside diameter m
\(d_i\) inside diameter m
\(k_w\) wall conductivity W/(m·K)
\(R_{fo}\) outside fouling resistance m²·K/W
\(R_{fi}\) inside fouling resistance m²·K/W
\(U_o\) U on outside area W/(m²·K)
\(U_i\) U on inside area W/(m²·K)
\(R_o\) total resistance m²·K/W
\(s_w\) wall share of resistance –

Method and standards

Resistances in series for a cylindrical wall, referred to the outside area.

Where it is used

  • Economiser, air heater, condenser and process exchanger design.
  • Checking the effect of fouling and cleaning.
  • Back-calculating fouling from plant data.

Common mistakes

  • Mixing inside and outside area bases.
  • Ignoring fouling, or adding it twice through a fouled film coefficient.
  • Using a gas coefficient for clean tubes on a sooty boiler.

Assumptions and limits

  • Thin or thick wall (log-mean conduction); no fins (use the finned-tube calculator for the gas side).

References

  • Thermal resistances in series for a cylindrical wall

Questions and answers

How is U calculated for a tube?

Add the resistances on one area basis. An economiser tube 51 × 4.5 mm with 60 W/(m²·K) outside, 5000 inside and fouling of 0.0005 and 0.0001 m²·K/W has U = 56.7 W/(m²·K) on the outside area.

Why is U close to the gas coefficient?

The gas side has by far the largest resistance; improving the water side hardly changes U, while fins on the gas side do.

Outside or inside area?

Either, as long as the area used with U matches; U_o A_o = U_i A_i.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.