Worked example
Example: 14 kg/s water at 70 bar(a), 150 to 230 °C; gas 37 kg/s at 380 °C; U 50. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feedwater flow | 50,400 kg/h |
| Feedwater pressure (absolute) | 70.000 bar |
| Feedwater in | 150.00 °C |
| Feedwater out | 230.00 °C |
| Flue gas flow | 133,200 kg/h |
| Mean specific heat of the flue gas | 1.0900 kJ/(kg·K) |
| Gas temperature entering | 380.00 °C |
| Overall heat transfer coefficient (on the area A, with fouling) | 50.000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Surface area needed | 780.84 m² |
| Economiser duty | 4,966.5 kW |
| Gas temperature leaving | 256.85 °C |
| Log mean temperature difference (counterflow) | 127.21 K |
| Approach to saturation at the outlet | 55.830 K |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_w\,(h_{w,2} - h_{w,1}) \qquad T_{g,2} = T_{g,1} - \frac{\dot Q}{\dot m_g c_{p,g}} \qquad LMTD = \frac{(T_{g,1} - T_{w,2}) - (T_{g,2} - T_{w,1})}{\ln\frac{T_{g,1} - T_{w,2}}{T_{g,2} - T_{w,1}}} \qquad A = \frac{\dot Q}{U\,LMTD}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_w\) | feedwater flow | kg/s |
| \(p_w\) | feedwater pressure | Pa |
| \(T_{w,1}\) | water in | K |
| \(T_{w,2}\) | water out | K |
| \(\dot m_g\) | gas flow | kg/s |
| \(c_{p,g}\) | gas specific heat | J/(kg·K) |
| \(T_{g,1}\) | gas in | K |
| \(U\) | overall coefficient | W/(m²·K) |
| \(A\) | surface area | m² |
| \(\dot Q\) | duty | W |
| \(T_{g,2}\) | gas out | K |
| \(LMTD\) | log mean temperature difference | K |
| \(\Delta T_{sat}\) | approach to saturation | K |
| \(h_{w,1}, h_{w,2}\) | water enthalpies (IF97) | J/kg |
Method and standards
Water duty from FireCAD's IAPWS-IF97 enthalpies, gas heat balance with mean specific heat, counterflow LMTD.
Where it is used
- Sizing economisers for new boilers and retrofits.
- HRSG economiser sections.
- Checking an existing economiser for higher duty.
Common mistakes
- Using a clean U for coal-fired service.
- Designing too close to saturation.
- Ignoring the cold-end metal temperature against acid dew point.
Assumptions and limits
- Counterflow, constant U and gas specific heat; water single-phase.
- U is referred to the area quoted (usually the gas-side surface) and must include fouling.
- Warnings appear when the water leaves within 20 K of saturation or the cold-end difference is under 10 K.
- At or above the critical pressure (22.064 MPa) there is no saturation temperature, so the approach is not shown.
References
- LMTD method
- IAPWS R7-97 IF97
Questions and answers
How big an economiser do I need?
14 kg/s of feedwater at 70 bar(a) heated from 150 to 230 °C takes 4.97 MW; gas at 380 °C (37 kg/s) leaves at 257 °C. The counterflow LMTD is 127 K, so U = 50 W/(m²·K) needs 781 m².
What approach should I keep?
The water should leave well below saturation (here 56 K) so it does not steam at part load; steaming economisers are a different design.
Bare or finned tubes?
Finned tubes put more area per metre for clean gas; for dusty coal gas bare tubes resist fouling and erosion.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.