Worked example
Example: Economiser cold end: gas 150 °C, water 105 °C, h_g 60, h_w 3000, ADP 125 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flue gas temperature at the cold end | 150.00 °C |
| Water or air temperature at the cold end | 105.00 °C |
| Gas-side film coefficient | 60.000 W/(m²·K) |
| Water- or air-side film coefficient | 3,000.0 W/(m²·K) |
| Acid dew point of the flue gas | 125.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Metal temperature at the cold end | 105.88 °C |
| Margin above the acid dew point | -19.118 K |
Open this example in the calculator and change any input.
Formula
\(T_m = \frac{h_g\,T_g + h_c\,T_c}{h_g + h_c} \qquad \Delta T = T_m - T_{adp}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_g\) | gas temperature at the cold end | K |
| \(T_c\) | water or air temperature at the cold end | K |
| \(h_g\) | gas-side coefficient | W/(m²·K) |
| \(h_c\) | water- or air-side coefficient | W/(m²·K) |
| \(T_{adp}\) | acid dew point | K |
| \(T_m\) | metal temperature | K |
| \(\Delta T\) | margin above the acid dew point | K |
Method and standards
Steady heat balance across a thin wall: the metal temperature divides the gas-to-coolant difference in proportion to the film resistances (wall and fouling resistance neglected).
Where it is used
- Setting minimum feedwater temperature for economisers.
- Air heater cold-end protection.
- Diagnosing cold-end corrosion and fouling.
Common mistakes
- Comparing the gas temperature, not the metal temperature, with the dew point.
- Using average instead of cold-end temperatures.
- Ignoring part load, when gas leaves colder.
Assumptions and limits
- Thin clean wall; local temperatures at the cold end.
- Both coefficients must be on the same area. For finned tubes or a large outside-to-inside diameter ratio, refer the gas-side coefficient to the coolant-side area (h_g × A_g/A_c, with fin efficiency) before entering it; otherwise the metal temperature is misstated.
References
- Thin-wall metal temperature from two film coefficients
Questions and answers
How cold is the metal at an economiser's cold end?
Close to the water, because the water side transfers heat far better. Gas at 150 °C and water at 105 °C with coefficients of 60 and 3000 W/(m²·K) give a metal at 106 °C, 19 K below a 125 °C acid dew point: acid will condense.
Why are air heaters safer?
Gas and air coefficients are similar, so the metal sits halfway between them: gas at 140 °C and air at 30 °C give about 88 °C, still below the dew point unless the air is preheated.
What can I do?
Raise the feedwater temperature (deaerator pressure, feed heater), preheat the air with a steam coil or recirculate hot air, or use corrosion-resistant cold-end elements.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.