Worked example
Example: 30 MW on 400 m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat absorbed by the water walls | 30.000 MW |
| Projected water-wall area | 400.00 m² |
| Peak-to-average factor | 1.6000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Average heat flux | 75.000 kW/m² |
| Peak heat flux | 120.00 kW/m² |
Open this example in the calculator and change any input.
Formula
\(q_{avg} = \frac{\dot Q_a}{A_p}, \quad q_{peak} = k_p q_{avg}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q_a\) | Heat absorbed by the water walls | W |
| \(A_p\) | Projected water-wall area | m² |
| \(k_p\) | Peak-to-average factor | - |
| \(q_{avg}\) | Average heat flux | W/m² |
| \(q_{peak}\) | Peak heat flux | W/m² |
Method and standards
Definition: the average flux is the heat absorbed by the water walls over their projected area; the peak flux applies a peak-to-average factor from the boiler maker or a measured profile.
Where it is used
- Furnace design checks.
- Tube failure investigations.
Common mistakes
- Tube surface area used.
Assumptions and limits
- The average is over the whole projected area; the peak factor gives the local maximum (burner zone, flame impingement). Its default, 1.6, is a FireCAD starting value, not a sourced figure.
- The heat input must be the water-wall absorption, not the heat released; the area is the flat projected wall area, with roof and hopper as your convention counts them.
- The peak flux is not compared with a CHF here: use the critical heat flux calculators.
References
- q = Q/A (definition); peak factor by design practice
Questions and answers
Why projected area?
Furnace absorption is customarily referred to the flat wall area, not the tube surface.
Peak factor?
Burner zone and flame impingement raise local flux; designs use a factor from experience.
Why care?
High flux with poor circulation or scale can lead to overheating and tube failure.