Worked example
Example: Bagasse furnace. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Adiabatic flame temperature | 1,600.0 °C |
| Flue gas flow | 160.00 t/h |
| Mean gas specific heat (T_exit to T_ad) | 1.3000 kJ/(kg·K) |
| Effective water-wall area | 600.00 m² |
| Effective furnace emissivity | 50.000 % |
| Wall surface temperature | 300.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Furnace exit gas temperature | 957.17 °C |
| Heat absorbed by the walls | 37.141 MW |
| Share of the available heat absorbed | 49.448 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_g \bar c_p (T_{ad} - T_e) = \sigma \varepsilon_{eff} A (T_e^4 - T_w^4) = \dot Q_r, \quad \dot Q_{ad} = \dot m_g \bar c_p (T_{ad} - T_w)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{ad}\) | Adiabatic flame temperature | K |
| \(\dot m_g\) | Flue gas flow | kg/s |
| \(\bar c_p\) | Mean gas specific heat (T_exit to T_ad) | J/(kg·K) |
| \(A\) | Effective water-wall area | m² |
| \(\varepsilon_{eff}\) | Effective furnace emissivity | - |
| \(T_w\) | Wall surface temperature | K |
| \(T_e\) | Furnace exit gas temperature | K |
| \(\dot Q_r\) | Heat absorbed by the walls | W |
| \(\dot Q_r/\dot Q_{ad}\) | Share of the available heat absorbed | - |
| \(\dot Q_{ad}\) | heat the gas would give up cooling from T_ad to the wall temperature | W |
| \(\sigma\) | Stefan–Boltzmann constant | W/(m²·K⁴) |
Method and standards
Well-stirred (zero-dimensional) furnace: the heat the gas loses from the adiabatic flame temperature to the exit equals the radiation from gas at the exit temperature to the walls; solved by bisection between the wall and flame temperatures. The share absorbed is relative to cooling the gas to the wall temperature, not to the fuel heat input.
Where it is used
- Furnace sizing.
- Fuel change studies.
Common mistakes
- Using the full-range cp at low temperatures.
Assumptions and limits
- Uniform gas temperature.
- The mean specific heat over T_e to T_ad depends on the unknown T_e: iterate it if needed.
References
- Well-stirred furnace model ṁ c̄_p (T_ad − T_e) = σ ε A (T_e⁴ − T_w⁴) (Hottel and Sarofim)
- Stefan–Boltzmann constant 5.670374419 × 10⁻⁸ W/m²K⁴ (CODATA 2018)
Questions and answers
Why does exit temperature matter?
It sets slagging of superheaters, superheat and the split between radiant and convective duty.
Is the furnace really well stirred?
No; the model is a first estimate. Tune the effective emissivity to a measured FEGT and then use it for changes.
Wet biomass?
Lower adiabatic temperature and higher gas flow give a cooler furnace exit.