Worked example
Example: Bagasse furnace. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Furnace volume | 450.00 m³ |
| Flue gas flow | 160.00 t/h |
| Mean furnace gas temperature | 1,000.0 °C |
| Flue gas molar mass | 28.500 kg/kmol |
| Furnace pressure (absolute) | 101.33 kPa |
| Heat input from fuel (GCV or NCV, as your limit states) | 75.000 MW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas density at furnace temperature | 0.27280 kg/m³ |
| Gas volume flow | 586,506 m³/h |
| Residence time | 2.7621 s |
| Volumetric heat release | 166.67 kW/m³ |
Open this example in the calculator and change any input.
Formula
\(\rho_g = \frac{p M_g}{1000\,R\,T_f}, \quad t_r = \frac{V_f \rho_g}{\dot m_g}, \quad q_v = \frac{\dot Q}{V_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Furnace volume | m³ |
| \(\dot m_g\) | Flue gas flow | kg/s |
| \(T_f\) | Mean furnace gas temperature | K |
| \(M_g\) | Flue gas molar mass | kg/kmol |
| \(p\) | Furnace pressure (absolute) | Pa |
| \(\dot Q\) | Heat input (fuel) | W |
| \(\rho_g\) | Gas density at furnace temperature | kg/m³ |
| \(\dot V_g\) | Gas volume flow | m³/s |
| \(t_r\) | Residence time | s |
| \(q_v\) | Volumetric heat release | W/m³ |
| \(R\) | universal gas constant, 8.314 J/(mol·K) (the 1000 converts \(M_g\) from kg/kmol) | J/(mol·K) |
Method and standards
Ideal-gas density at the mean furnace temperature; residence time is the furnace volume over the gas volume flow.
Where it is used
- Furnace sizing and checks.
- Fuel change studies.
Common mistakes
- Gas flow at normal conditions used as actual.
Assumptions and limits
- Uniform temperature; plug flow through the whole volume.
- The volumetric heat release is on the basis (GCV or NCV) of the heat input entered.
- A note appears below 2 s, the residence time waste-fuel rules often require.
References
- Ideal gas density ρ = pM/(RT); residence time = V/V̇; heat release = Q/V
Questions and answers
Why residence time?
Fuel needs time at temperature to burn out; emissions rules for waste fuels often ask for it.
Mean gas temperature?
Between the flame and the furnace exit; use a design estimate.
Molar mass of flue gas?
Close to 28–29 kg/kmol; wet biomass flue gas is a little lighter.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.