Economiser Water Velocity and Pressure Drop

Water velocity, Reynolds number, Colebrook friction factor and pressure drop in an economiser's parallel circuits with bend losses (IF97 water).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Economiser and air preheater

Inputs

Examples: 60 t/h, 24 circuitsFewer circuits

Results

Static head of vertical circuits is not included; add it for up-flow and down-flow passes.

Water velocity0.69181m/s
Reynolds number161,598
Darcy friction factor0.022070
Pressure drop0.18860bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 t/h, 24 circuits. The inputs, in the units selected above:

InputValue
Feedwater flow60.000 t/h
Parallel tube circuits24.000 -
Tube inside diameter38.100 mm
Length of one circuit120.00 m
Roughness0.046000 mm
Bend and header losses (sum of K)20.000 -
Water pressure (absolute)75.000 bar
Mean water temperature190.00 °C

Applying the formula below gives:

ResultValue
Water velocity0.69181 m/s
Reynolds number161,598
Darcy friction factor0.022070
Pressure drop0.18860 bar

Open this example in the calculator and change any input.

Formula

\(v = \frac{\dot m}{n \rho \pi d_i^2/4}, \quad \Delta p = \left(f\frac{L}{d_i} + \Sigma K\right)\frac{\rho v^2}{2}\)

\(Re = \frac{\rho v d_i}{\mu}, \quad f = \frac{64}{Re}\ (Re < 2300), \quad \frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\varepsilon/d_i}{3.7} + \frac{2.51}{Re\sqrt f}\right)\ \text{otherwise}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Feedwater flow kg/s
\(n\) Parallel tube circuits -
\(d_i\) Tube inside diameter m
\(L\) Length of one circuit m
\(\varepsilon\) Roughness m
\(\Sigma K\) Bend and header losses (sum of K) -
\(p\) Water pressure (absolute) Pa
\(T\) Mean water temperature K
\(v\) Water velocity m/s
\(Re\) Reynolds number -
\(f\) Darcy friction factor -
\(\Delta p\) Pressure drop Pa
\(\rho\), \(\mu\) water density and viscosity at \(p\), \(T\) (IAPWS-IF97, IAPWS 2008) kg/m³, Pa·s

Method and standards

Darcy–Weisbach with the Colebrook friction factor (laminar 64/Re below Re 2300), water properties from FireCAD's IAPWS-IF97 and IAPWS 2008 viscosity.

Where it is used

  • Economiser design.
  • Feed pump head checks.

Common mistakes

  • Total tubes used for circuits.

Assumptions and limits

  • Single-phase water; static head of vertical passes not included.
  • The friction factor jumps from 64/Re to Colebrook at Re 2300; in the transition range the result is uncertain and a note appears.
  • A note appears when the velocity is outside 0.6–1.5 m/s.

References

  • Darcy–Weisbach with Colebrook friction factor; water properties from IAPWS-IF97 and IAPWS 2008 viscosity

Questions and answers

Typical water velocity?

About 0.6–1.5 m/s to keep tubes cooled and free of deposits without large pressure drop.

Why does it matter for the feed pump?

Economiser drop adds directly to the pump head.

Bend losses?

Each 180° return bend adds a K of order 0.2–0.5; sum them per circuit.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.