Worked example
Example: 60 t/h, 24 circuits. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feedwater flow | 60.000 t/h |
| Parallel tube circuits | 24.000 - |
| Tube inside diameter | 38.100 mm |
| Length of one circuit | 120.00 m |
| Roughness | 0.046000 mm |
| Bend and header losses (sum of K) | 20.000 - |
| Water pressure (absolute) | 75.000 bar |
| Mean water temperature | 190.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water velocity | 0.69181 m/s |
| Reynolds number | 161,598 |
| Darcy friction factor | 0.022070 |
| Pressure drop | 0.18860 bar |
Open this example in the calculator and change any input.
Formula
\(v = \frac{\dot m}{n \rho \pi d_i^2/4}, \quad \Delta p = \left(f\frac{L}{d_i} + \Sigma K\right)\frac{\rho v^2}{2}\)
\(Re = \frac{\rho v d_i}{\mu}, \quad f = \frac{64}{Re}\ (Re < 2300), \quad \frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\varepsilon/d_i}{3.7} + \frac{2.51}{Re\sqrt f}\right)\ \text{otherwise}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Feedwater flow | kg/s |
| \(n\) | Parallel tube circuits | - |
| \(d_i\) | Tube inside diameter | m |
| \(L\) | Length of one circuit | m |
| \(\varepsilon\) | Roughness | m |
| \(\Sigma K\) | Bend and header losses (sum of K) | - |
| \(p\) | Water pressure (absolute) | Pa |
| \(T\) | Mean water temperature | K |
| \(v\) | Water velocity | m/s |
| \(Re\) | Reynolds number | - |
| \(f\) | Darcy friction factor | - |
| \(\Delta p\) | Pressure drop | Pa |
| \(\rho\), \(\mu\) | water density and viscosity at \(p\), \(T\) (IAPWS-IF97, IAPWS 2008) | kg/m³, Pa·s |
Method and standards
Darcy–Weisbach with the Colebrook friction factor (laminar 64/Re below Re 2300), water properties from FireCAD's IAPWS-IF97 and IAPWS 2008 viscosity.
Where it is used
- Economiser design.
- Feed pump head checks.
Common mistakes
- Total tubes used for circuits.
Assumptions and limits
- Single-phase water; static head of vertical passes not included.
- The friction factor jumps from 64/Re to Colebrook at Re 2300; in the transition range the result is uncertain and a note appears.
- A note appears when the velocity is outside 0.6–1.5 m/s.
References
- Darcy–Weisbach with Colebrook friction factor; water properties from IAPWS-IF97 and IAPWS 2008 viscosity
Questions and answers
Typical water velocity?
About 0.6–1.5 m/s to keep tubes cooled and free of deposits without large pressure drop.
Why does it matter for the feed pump?
Economiser drop adds directly to the pump head.
Bend losses?
Each 180° return bend adds a K of order 0.2–0.5; sum them per circuit.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.