Radiation from Flue Gas to Walls (Hottel Gray-Wall Factor)

Net radiant heat flux from hot gas to cooler walls from gas emissivity and absorptivity, the (ε_w + 1)/2 wall factor and the temperatures.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoilerBurner and furnace

Inputs

Examples: 1100 °C gas, 300 °C tubesConvection pass

Results

Take ε_g and α_g from the gas composition and mean beam length.

Net radiant heat flux to the wall43.707kW/m²
Radiation coefficient q/(T_g − T_w)54.634W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1100 °C gas, 300 °C tubes. The inputs, in the units selected above:

InputValue
Gas temperature1,100.0 °C
Wall (tube surface) temperature300.00 °C
Gas emissivity at T_g25.000 %
Gas absorptivity for wall radiation30.000 %
Wall emissivity80.000 %

Applying the formula below gives:

ResultValue
Net radiant heat flux to the wall43.707 kW/m²
Radiation coefficient q/(T_g − T_w)54.634 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(q = \sigma\frac{\varepsilon_w + 1}{2}\left(\varepsilon_g T_g^4 - \alpha_g T_w^4\right), \quad h_r = \frac{q}{T_g - T_w}\)

Variables

Symbol Meaning SI unit
\(T_g\) Gas temperature K
\(T_w\) Wall (tube surface) temperature K
\(\varepsilon_g\) Gas emissivity at T_g -
\(\alpha_g\) Gas absorptivity for wall radiation -
\(\varepsilon_w\) Wall emissivity -
\(q\) Net radiant heat flux to the wall W/m²
\(h_r\) Radiation coefficient q/(T_g − T_w) W/(m²·K)

Method and standards

Hottel's gray-wall approximation: the net flux from a gray gas to a gray enclosure wall, with the effective wall emissivity \((\varepsilon_w + 1)/2\) for walls of emissivity above about 0.7.

Where it is used

  • Superheater and convection bank radiation.
  • Furnace design checks.

Common mistakes

  • Celsius in the fourth power.

Assumptions and limits

  • Gray walls, uniform gas. The flux is per unit of the wall (enclosure) surface the gas sees; for tube banks use it with the area the coefficient is referred to.
  • The gas emissivity must be above zero and the net flux positive; inconsistent emissivity and absorptivity are rejected.

References

  • q = σ (ε_w + 1)/2 (ε_g T_g⁴ − α_g T_w⁴) (Hottel and Sarofim, Radiative Transfer, McGraw-Hill, 1967; McAdams, Heat Transmission, 3rd ed., 1954; Perry's Chemical Engineers' Handbook)
  • Stefan–Boltzmann constant 5.670374419 × 10⁻⁸ W/m²K⁴ (CODATA 2018)

Questions and answers

Why is absorptivity different from emissivity?

The gas absorbs radiation from the cooler wall with a different spectrum than it emits at its own temperature.

Why (ε_w + 1)/2?

Radiation not absorbed on first strike is reflected and partly absorbed elsewhere in the enclosure.

Luminous flames?

Soot and ash raise ε_g well above the clean-gas value.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.