Sulphuric Acid Dew Point of Flue Gas

Acid dew point by Verhoff–Banchero from flue gas water vapour and SO₃, with SO₃ entered directly or estimated from fuel sulphur.

Thermal power plantRefinery and petrochemicalChemical and fertiliserThermic fluid heatingASME PTC 4 (fired steam generators)BoilerStack and chimney

Inputs

Examples: Coal, 2.5 % S, 2 % conversionHeavy fuel oil, 3 % S, 3 % conversionDirect SO3, 15 ppm

Wet basis, by volume.

Estimate from fuel sulphur

Nm³ of wet flue gas per kg of fuel at 0 °C and 101.325 kPa (normal), wet basis, as the combustion calculator gives it. A volume at 15 or 20 °C understates SO₂ by 5–7 %.
Typically 1–3 % for coal, 2–5 % for heavy oil with vanadium.

Enter SO₃ directly

Results

Acid dew point150.14°C
SO₃ used in the correlation0.003496%
SO₂ from the fuel sulphur0.17478%
Partial pressure of water vapour0.10132bar
Partial pressure of SO₃3.5419e-05bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal, 2.5 % S, 2 % conversion. The inputs, in the units selected above:

InputValue
Water vapour in flue gas10.000 %
Flue gas pressure (absolute)1.0132 bar
SO₃ sourceEstimate from fuel sulphur
Sulphur in fuel (as fired)2.5000 %
Specific wet flue gas volume10.000 Nm³/kg
SO₂ → SO₃ conversion2.0000 %
SO₃ in flue gas0 ppm

Applying the formula below gives:

ResultValue
Acid dew point150.14 °C
SO₃ used in the correlation0.003496 %
SO₂ from the fuel sulphur0.17478 %
Partial pressure of water vapour0.10132 bar
Partial pressure of SO₃3.5419e-05 bar

Open this example in the calculator and change any input.

Formula

Verhoff and Banchero (1974), partial pressures in mmHg:

\(\frac{1000}{T_{dp}} = 2.276 - 0.02943\,\ln p_{H_2O} - 0.0858\,\ln p_{SO_3} + 0.0062\,\ln p_{H_2O}\,\ln p_{SO_3}\)

\(p_{H_2O} = y_{H_2O}\,p \qquad p_{SO_3} = y_{SO_3}\,p\)

SO₃ estimated from the fuel: sulphur burns to SO₂ one mole per mole, a fraction \(f_{SO_3}\) oxidises further:

\(y_{SO_2} = \frac{S / M_S \cdot V_m}{V_g} \qquad y_{SO_3} = f_{SO_3}\, y_{SO_2}\)

Variables

Symbol Meaning SI unit
\(T_{dp}\) sulphuric acid dew point K
\(y_{H_2O}\) water vapour in wet flue gas, volume fraction –
\(p\) absolute flue gas pressure Pa
\(\text{mode}\) SO₃ estimated from fuel sulphur, or entered –
\(S\) sulphur in the fuel as fired, mass fraction –
\(M_S\) molar mass of sulphur, 32.06 kg/kmol
\(V_m\) molar volume at 0 °C and 101.325 kPa, 22.414 Nm³/kmol
\(V_g\) wet flue gas volume per kg fuel, at 0 °C and 101.325 kPa Nm³/kg
\(f_{SO_3}\) fraction of SO₂ converted to SO₃ –
\(y_{SO_2}\) SO₂ in wet flue gas, volume fraction –
\(y_{SO_3,in}\) SO₃ entered directly, volume fraction –
\(y_{SO_3}\) SO₃ used in the correlation –
\(p_{H_2O}\) partial pressure of water vapour (converted to mmHg in the correlation) Pa
\(p_{SO_3}\) partial pressure of SO₃ (converted to mmHg in the correlation) Pa

Method and standards

The Verhoff–Banchero correlation is widely used in boiler and air-heater design practice. It was fitted to measured dew points with partial pressures in mmHg; the calculator converts the SI partial pressures to mmHg (1 mmHg = 133.322 Pa) before taking the logarithms. Entering the pressures in atmospheres instead, a common mistake, gives dew points about 125 K too low.

Where it is used

  • Setting the minimum flue gas exit temperature of boilers burning coal, oil or sulphur-bearing gas.
  • Choosing the cold-end metal temperature of economisers and air preheaters, and steam coil air heaters.
  • Stack and duct material selection and insulation design.

Common mistakes

  • Comparing the dew point with the flue gas temperature instead of the coldest metal temperature.
  • Assuming all sulphur goes to SO₃: only a few per cent does; the SO₃ share sets the dew point.
  • Ignoring part load, when the gas leaves colder and the air heater cold end is coldest.

Assumptions and limits

  • Fitted range roughly 5–15 % H₂O and 1–100 ppm SO₃; outside it the result is indicative.
  • The SO₂ estimate assumes all fuel sulphur reaches the gas (no sulphur retained in ash or sorbent). For fluidised beds with limestone, enter the measured SO₂ or SO₃ directly.
  • A separate water dew point governs when SO₃ is nil.

References

  • Verhoff & Banchero (1974)
  • ASME PTC 4.3 air heaters

Questions and answers

Why does the dew point depend so weakly on water but strongly on SO₃?

Per doubling the two are similar: at 10 % water and 15 ppm SO₃, doubling SO₃ raises the dew point about 7 K and doubling water also about 7 K. But SO₃ varies over orders of magnitude (1 to 50 ppm moves the dew point about 38 K), while water in flue gas stays within about 5–15 % (about 11 K).

How much SO₂ converts to SO₃?

Typically 1–3 % in coal-fired boilers, more with vanadium-bearing heavy fuel oil (2–5 %) and across SCR catalysts (0.5–1.5 % additional). It is the least certain input; try the range.

What metal temperature should I design for?

Keep the cold-end minimum metal temperature at or above the acid dew point plus a margin (commonly 10–15 K). Corrosion rate peaks 20–40 K below the dew point, not at it.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.