FireCADCalc

Superheater Duty and Surface Area (LMTD)

Superheater duty from saturated to final steam temperature, flue gas outlet temperature and surface area by LMTD for counterflow or parallel flow (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 50 t/h to 485 °C at 66 bar(a); gas 60 kg/s at 950 °C; U 70; counterflowSame, parallel flow10 t/h to 350 °C at 18 bar(a); gas 12 kg/s at 750 °C; U 55; counterflowSecondary stage 400 to 485 °C at 66 bar(a), cross-flow F 0.92

From the overall-coefficient calculator or the boiler maker, on the same surface as the area (usually the outside tube surface); radiant superheaters need a different method.
Leave at 0 for a single superheater fed with dry saturated steam from the drum. For a secondary stage or after an attemperator, enter the steam temperature entering this stage (at or above saturation).
1 for pure counterflow or parallel flow. Cross-flow and multi-pass banks: read F from the charts for the arrangement (Bowman, Mueller and Nagle; TEMA), typically 0.85 to 0.98.

Results

Surface area needed234.51m²
Superheater duty8,362.7kW
Gas temperature leaving838.50°C
Log mean temperature difference509.44K
Saturation temperature at the steam pressure281.88°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h to 485 °C at 66 bar(a); gas 60 kg/s at 950 °C; U 70; counterflow. The inputs, in the units selected above:

InputValue
Steam flow50,000 kg/h
Steam pressure (absolute)66.000 bar
Final steam temperature485.00 °C
Flue gas flow216,000 kg/h
Mean specific heat of the flue gas1.2500 kJ/(kg·K)
Gas temperature entering950.00 °C
Overall heat transfer coefficient70.000 W/(m²·K)
Flow arrangementCounterflow
Steam inlet temperature (0 = dry saturated)-273.15 °C
LMTD correction factor for the bank arrangement100.00 %

Applying the formula below gives:

ResultValue
Surface area needed234.51 m²
Superheater duty8,362.7 kW
Gas temperature leaving838.50 °C
Log mean temperature difference509.44 K
Saturation temperature at the steam pressure281.88 °C

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_s\,(h(p, T_{s,2}) - h(p, T_{s,1})) \qquad T_{g,2} = T_{g,1} - \frac{\dot Q}{\dot m_g c_{p,g}} \qquad LMTD = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1/\Delta T_2)} \qquad A = \frac{\dot Q}{U\,F\,LMTD}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam flow kg/s
\(p\) steam pressure Pa
\(T_{s,2}\) final steam temperature K
\(\dot m_g\) gas flow kg/s
\(c_{p,g}\) gas specific heat J/(kg·K)
\(T_{g,1}\) gas temperature in K
\(U\) overall coefficient W/(m²·K)
\(\text{arr}\) counterflow or parallel flow –
\(A\) surface area m²
\(\dot Q\) duty W
\(T_{g,2}\) gas temperature out K
\(LMTD\) log mean temperature difference K
\(T_{s,1}\) steam inlet temperature; dry saturated (\(T_{sat}\), enthalpy \(h_g\)) when entered as 0 K
\(T_{sat}\) saturation temperature at the steam pressure K
\(F\) LMTD correction factor for the bank arrangement –
\(h\) steam enthalpy (IF97) J/kg
\(\Delta T_1, \Delta T_2\) end temperature differences K

Method and standards

Steam duty from FireCAD's IAPWS-IF97 enthalpies between the inlet state (dry saturated, or the superheated inlet temperature of a secondary stage) and the final state; gas heat balance with a mean specific heat; LMTD for pure counterflow or parallel flow, multiplied by the correction factor F the user reads for a cross-flow or multi-pass bank.

Where it is used

  • Superheater sizing at proposal stage.
  • Checking an existing superheater for a new steam temperature.
  • Comparing counterflow and parallel flow.

Common mistakes

  • Ignoring radiation in high-temperature superheaters.
  • Using an LMTD without the cross-flow correction for multi-pass banks.
  • Forgetting attemperator spray, which changes the steam flow through the superheater.

Assumptions and limits

  • The steam pressure is the same at inlet and outlet (the steam-side pressure drop is neglected). Dry saturated steam enters unless an inlet temperature is entered, for a secondary stage or after an attemperator; wet drum steam cannot be entered. Attemperator spray changes the steam flow: enter the flow through this stage.
  • Constant U and gas specific heat. F is entered, not computed: 1 means pure counter or parallel flow; cross-flow and multi-pass banks have F below 1 and need more area.
  • U and the area are on the same surface, usually the outside tube surface.

References

  • LMTD method
  • IAPWS R7-97 IF97

Questions and answers

How big a superheater do I need?

50 t/h superheated to 485 °C at 66 bar(a) takes 8.36 MW. Gas entering at 950 °C (60 kg/s) leaves at 839 °C; in counterflow the LMTD is 509 K, so with U = 70 W/(m²·K) the area is 235 m².

Counterflow or parallel flow?

Counterflow needs less area; parallel flow keeps the hottest steam away from the hottest gas, so tube metal runs cooler. Primary superheaters are often counterflow, finishing stages parallel.

What U should I use?

From the overall-coefficient calculator with gas-side convection and radiation; radiant superheaters need a radiation method instead.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.