Worked example
Example: 50 t/h to 485 °C at 66 bar(a); gas 60 kg/s at 950 °C; U 70; counterflow. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 50,000 kg/h |
| Steam pressure (absolute) | 66.000 bar |
| Final steam temperature | 485.00 °C |
| Flue gas flow | 216,000 kg/h |
| Mean specific heat of the flue gas | 1.2500 kJ/(kg·K) |
| Gas temperature entering | 950.00 °C |
| Overall heat transfer coefficient | 70.000 W/(m²·K) |
| Flow arrangement | Counterflow |
| Steam inlet temperature (0 = dry saturated) | -273.15 °C |
| LMTD correction factor for the bank arrangement | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Surface area needed | 234.51 m² |
| Superheater duty | 8,362.7 kW |
| Gas temperature leaving | 838.50 °C |
| Log mean temperature difference | 509.44 K |
| Saturation temperature at the steam pressure | 281.88 °C |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_s\,(h(p, T_{s,2}) - h(p, T_{s,1})) \qquad T_{g,2} = T_{g,1} - \frac{\dot Q}{\dot m_g c_{p,g}} \qquad LMTD = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1/\Delta T_2)} \qquad A = \frac{\dot Q}{U\,F\,LMTD}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam flow | kg/s |
| \(p\) | steam pressure | Pa |
| \(T_{s,2}\) | final steam temperature | K |
| \(\dot m_g\) | gas flow | kg/s |
| \(c_{p,g}\) | gas specific heat | J/(kg·K) |
| \(T_{g,1}\) | gas temperature in | K |
| \(U\) | overall coefficient | W/(m²·K) |
| \(\text{arr}\) | counterflow or parallel flow | – |
| \(A\) | surface area | m² |
| \(\dot Q\) | duty | W |
| \(T_{g,2}\) | gas temperature out | K |
| \(LMTD\) | log mean temperature difference | K |
| \(T_{s,1}\) | steam inlet temperature; dry saturated (\(T_{sat}\), enthalpy \(h_g\)) when entered as 0 | K |
| \(T_{sat}\) | saturation temperature at the steam pressure | K |
| \(F\) | LMTD correction factor for the bank arrangement | – |
| \(h\) | steam enthalpy (IF97) | J/kg |
| \(\Delta T_1, \Delta T_2\) | end temperature differences | K |
Method and standards
Steam duty from FireCAD's IAPWS-IF97 enthalpies between the inlet state (dry saturated, or the superheated inlet temperature of a secondary stage) and the final state; gas heat balance with a mean specific heat; LMTD for pure counterflow or parallel flow, multiplied by the correction factor F the user reads for a cross-flow or multi-pass bank.
Where it is used
- Superheater sizing at proposal stage.
- Checking an existing superheater for a new steam temperature.
- Comparing counterflow and parallel flow.
Common mistakes
- Ignoring radiation in high-temperature superheaters.
- Using an LMTD without the cross-flow correction for multi-pass banks.
- Forgetting attemperator spray, which changes the steam flow through the superheater.
Assumptions and limits
- The steam pressure is the same at inlet and outlet (the steam-side pressure drop is neglected). Dry saturated steam enters unless an inlet temperature is entered, for a secondary stage or after an attemperator; wet drum steam cannot be entered. Attemperator spray changes the steam flow: enter the flow through this stage.
- Constant U and gas specific heat. F is entered, not computed: 1 means pure counter or parallel flow; cross-flow and multi-pass banks have F below 1 and need more area.
- U and the area are on the same surface, usually the outside tube surface.
References
- LMTD method
- IAPWS R7-97 IF97
Questions and answers
How big a superheater do I need?
50 t/h superheated to 485 °C at 66 bar(a) takes 8.36 MW. Gas entering at 950 °C (60 kg/s) leaves at 839 °C; in counterflow the LMTD is 509 K, so with U = 70 W/(m²·K) the area is 235 m².
Counterflow or parallel flow?
Counterflow needs less area; parallel flow keeps the hottest steam away from the hottest gas, so tube metal runs cooler. Primary superheaters are often counterflow, finishing stages parallel.
What U should I use?
From the overall-coefficient calculator with gas-side convection and radiation; radiant superheaters need a radiation method instead.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.