Worked example
Example: 50 t/h at 66 bar(a) / 520 °C, 2 t/h spray at 150 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow in | 50,000 kg/h |
| Steam pressure (absolute) | 66.000 bar |
| Steam temperature in | 520.00 °C |
| Spray water flow | 2,000.0 kg/h |
| Spray water pressure (absolute) | 90.000 bar |
| Spray water temperature | 150.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam temperature out | 474.91 °C |
| Superheat remaining | 193.03 K |
| Steam flow out | 52,000 kg/h |
| Steam enthalpy out | 3,355.2 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(h_2 = \frac{\dot m_s h_s + \dot m_w h_w}{\dot m_s + \dot m_w} \qquad T_2 = T(p, h_2) \qquad \Delta T_{sh} = T_2 - T_{sat}(p)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam flow in | kg/s |
| \(p\) | steam pressure | Pa |
| \(T_s\) | steam temperature in | K |
| \(\dot m_w\) | spray water flow | kg/s |
| \(p_w\) | spray water pressure | Pa |
| \(T_w\) | spray water temperature | K |
| \(T_2\) | steam temperature out | K |
| \(\Delta T_{sh}\) | superheat remaining | K |
| \(\dot m_2\) | steam flow out | kg/s |
| \(h_2\) | outlet enthalpy | J/kg |
| \(h_s, h_w\) | steam and water enthalpies (IF97) | J/kg |
Method and standards
Adiabatic mixing at the steam pressure with enthalpies and the outlet state from FireCAD's IAPWS-IF97.
Where it is used
- Checking attemperator control range.
- Investigating steam temperature excursions.
- PRDS outlet temperatures.
Common mistakes
- Spraying close to saturation.
- Forgetting the spray adds to the steam flow.
- Using spray water pressure below steam pressure.
Assumptions and limits
- Complete evaporation and mixing; no heat loss. The spray water enthalpy at its own pressure is unchanged through the valve and nozzle (isenthalpic throttling), so the balance is on enthalpy at the steam pressure.
- If the outlet is wet, the temperature shown is the saturation temperature and a warning gives the outlet dryness.
- The 10 K superheat warning is a FireCAD rule-of-thumb margin, not a code value.
- Above the critical pressure (220.64 bar) there is no saturation temperature, so the superheat is not shown.
References
- IAPWS R7-97 IF97
- adiabatic mixing
Questions and answers
What temperature does a spray give?
50 t/h of steam at 66 bar(a) and 520 °C with 2 t/h of 150 °C spray water leaves at 475 °C, with 193 K of superheat left.
How is this different from the spray-water calculator?
That one finds the spray for a target temperature; this one finds the temperature a spray flow gives, which is what you see when the valve sticks or is set by hand.
Why keep superheat after the spray?
Water droplets must evaporate before the next bend or the turbine; a margin above saturation makes sure they do.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.