Worked example
Example: 5 t/h condensate at 90 °C vs make-up at 30 °C, coal 18.6 MJ/kg, 80 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condensate returned | 5,000.0 kg/h |
| Condensate temperature at the feed tank | 90.000 °C |
| Make-up water temperature | 30.000 °C |
| Pressure of the water (absolute) | 2.0000 bar |
| Boiler efficiency (on GCV) | 80.000 % |
| Gross calorific value of the fuel | 18,600 kJ/kg |
| Operating hours per year | 8,000.0 h |
| Density of the make-up water saved (for the yearly volume) | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel saved | 84.390 kg/h |
| Fuel saved per year | 675.12 t |
| Water saved per year | 40,080 m³ |
| Heat recovered | 348.81 kW |
| Condensate enthalpy | 377.07 kJ/kg |
| Make-up water enthalpy | 125.92 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_c\,(h_c - h_{mu}) \qquad \dot m_f = \frac{\dot Q}{\eta\;GCV} \qquad m_f = \dot m_f\,t_{op} \qquad V_w = \frac{\dot m_c\,t_{op}}{\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | condensate returned | kg/s |
| \(T_c\) | condensate temperature at the feed tank | K |
| \(T_{mu}\) | make-up water temperature | K |
| \(p\) | pressure of the water, absolute | Pa |
| \(\eta\) | boiler efficiency on GCV | – |
| \(GCV\) | gross calorific value of the fuel | J/kg |
| \(t_{op}\) | operating hours per year | s |
| \(\rho\) | water density | kg/m³ |
| \(\dot m_f\) | fuel saved | kg/s |
| \(m_f\) | fuel saved per year | kg |
| \(V_w\) | water saved per year | m³ |
| \(\dot Q\) | heat recovered | W |
| \(h_c\) | condensate enthalpy | J/kg |
| \(h_{mu}\) | make-up water enthalpy | J/kg |
Method and standards
Energy balance on the feed tank: the heat in the returned condensate above the make-up temperature no longer has to come from fuel. Enthalpies of compressed water from FireCAD's IAPWS-IF97.
Where it is used
- Justifying condensate recovery systems and pumping traps.
- Water and chemical audits.
- Steam cost studies in process plants.
Common mistakes
- Counting only the heat and forgetting water and chemical savings.
- Assuming condensate returns at steam temperature: it cools in the lines and loses flash steam.
- Returning contaminated condensate that harms the boiler.
Assumptions and limits
- Heat losses of the return line and pumping energy are not deducted.
- The boiler efficiency is taken as unchanged; a hotter feed can slightly lower it when there is no economiser.
- Treatment and chemical savings are not included.
- The saving is referred to make-up water entering at \(T_{mu}\) at the same point. If the make-up would otherwise be heated by deaerator steam or blowdown heat recovery, the fuel saved differs.
- The yearly water volume uses the density you enter for the make-up water (998 kg/m³ at about 20 °C by default), not the density of the hot condensate.
References
- IAPWS R7-97(2012) IF97 (enthalpies)
Questions and answers
How much fuel does returning condensate save?
Returning 5 t/h at 90 °C in place of make-up at 30 °C brings back 349 kW. At 80 % efficiency on coal of 18.6 MJ/kg that saves 84 kg/h, 675 t a year over 8 000 hours.
Is the water saving counted?
Yes, separately: 40 000 m³ a year in that example, plus the chemicals and treatment the make-up would need.
What about flash steam?
Condensate returned from a higher pressure flashes when it reaches the feed tank. Enter the temperature at the tank, or recover the flash with the flash steam calculator.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.