FireCADCalc

Heat Required to Generate Steam from Feedwater

Heat to turn feedwater into wet, dry saturated or superheated steam, split into sensible, latent and superheat parts, with the fuel needed at a boiler efficiency (IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 10 kg/cm² g dry saturated from 60 °C feed, 10 t/h, 80 %, 4 000 kcal/kg12 bar g wet 0.95 from 80 °C, 5 t/h, 75 %, 3 500 kcal/kg40 bar(a) at 400 °C from 105 °C, 20 t/h, 85 %, 10 000 kcal/kg oil

Fuel

Results

The feedwater enthalpy is taken at the boiler pressure (compressed water); exam answers that use 4.187 × t from steam tables at atmospheric pressure differ by a few kJ/kg.

Enthalpy of the feedwater252.06kJ/kg
Enthalpy of the steam2,780.7kJ/kg
Sensible heat, feedwater to boiling (h_f − h_fw)529.37kJ/kg
Latent heat added (x h_fg)1,999.3kJ/kg
Heat of superheat (h − h_g)0kJ/kg
Total heat per kg of steam2,528.6kJ/kg
Heat to the steam7,024.0kW
Fuel burnt1,887.4kg/h
Evaporation ratio (steam per kg of fuel)5.2984kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 kg/cm² g dry saturated from 60 °C feed, 10 t/h, 80 %, 4 000 kcal/kg. The inputs, in the units selected above:

InputValue
Boiler pressure (absolute)9.8066 bar g
Feedwater temperature60.000 °C
Steam producedDry saturated
Dryness fraction (wet steam)95.000 %
Steam temperature (superheated)250.00 °C
Steam generated10,000 kg/h
Boiler efficiency80.000 %
Calorific value of the fuel (same basis, GCV or NCV, as the efficiency)16,747 kJ/kg

Applying the formula below gives:

ResultValue
Enthalpy of the feedwater252.05 kJ/kg
Enthalpy of the steam2,780.1 kJ/kg
Sensible heat, feedwater to boiling (h_f − h_fw)525.91 kJ/kg
Latent heat added (x h_fg)2,002.1 kJ/kg
Heat of superheat (h − h_g)0 kJ/kg
Total heat per kg of steam2,528.0 kJ/kg
Heat to the steam7,022.3 kW
Fuel burnt1,886.9 kg/h
Evaporation ratio (steam per kg of fuel)5.2997 kg/kg

Open this example in the calculator and change any input.

Formula

\(q = h_s - h_{fw} = \underbrace{(h_f - h_{fw})}_{\text{sensible}} + \underbrace{x\,h_{fg}}_{\text{latent}} + \underbrace{(h - h_g)}_{\text{superheat}}\)

\(\dot Q = \dot m_s\, q, \quad \dot m_f = \frac{\dot Q}{\eta_b\, GCV}, \quad ER = \frac{\dot m_s}{\dot m_f} = \frac{\eta_b\, GCV}{q}\)

Variables

Symbol Meaning SI unit
\(p\) Boiler pressure (absolute) Pa
\(T_{fw}\) Feedwater temperature K
\(\text{state}\) Steam produced -
\(x\) Dryness fraction (wet steam) -
\(T_{sup}\) Steam temperature (superheated) K
\(\dot m_s\) Steam generated kg/s
\(\eta_b\) Boiler efficiency -
\(GCV\) Calorific value of the fuel (same basis as the efficiency) J/kg
\(h_{fw}\) Enthalpy of the feedwater J/kg
\(h_s\) Enthalpy of the steam J/kg
\(q_{sens}\) Sensible heat, feedwater to boiling (h_f − h_fw) J/kg
\(q_{lat}\) Latent heat added (x h_fg) J/kg
\(q_{sup}\) Heat of superheat (h − h_g) J/kg
\(q\) Total heat per kg of steam J/kg
\(\dot Q\) Heat to the steam W
\(\dot m_f\) Fuel burnt kg/s
\(ER\) Evaporation ratio (steam per kg of fuel) kg/kg

Method and standards

Enthalpies from IAPWS-IF97: feedwater as compressed water at the boiler pressure, saturation properties and superheated steam at the boiler pressure.

Worked example

A boiler makes 10 t/h of dry saturated steam at 10 kg/cm² g from feedwater at 60 °C. Efficiency 80 %, coal 4000 kcal/kg.

  • Feedwater h_fw = 252.0 kJ/kg; h_f = 778.0 kJ/kg; h_g = 2780.1 kJ/kg at 10.81 bar absolute
  • Heat per kg = 2780.1 − 252.0 = 2528.0 kJ/kg
  • Heat to steam = 10 000/3600 × 2528.0 = 7022 kW
  • Coal = 7022 / (0.8 × 16 747) = 0.524 kg/s = 1887 kg/h; evaporation ratio 5.3

Where it is used

  • Boiler attendant examinations: heat to raise steam and fuel burnt.
  • Estimating fuel for a planned steam demand.
  • Explaining where the fuel's heat goes in a boiler.

Common mistakes

  • Using gauge pressure in the steam tables.
  • Forgetting the feedwater's own heat (using h_s instead of h_s − h_fw).
  • Dividing by efficiency twice, or not at all.

Assumptions and limits

  • Steady operation; blowdown and losses are inside the efficiency.
  • Feedwater must be liquid at the boiler pressure.
  • The efficiency and the calorific value must be on the same basis (both gross or both net); mixing them misstates the fuel.
  • The evaporation ratio is computed as η GCV / q, so it is shown even when the steam flow is zero.
  • A gauge pressure is converted to absolute with the standard atmosphere (101.325 kPa), not the site barometer.

References

  • IAPWS-IF97 (water and steam)

Questions and answers

How much heat makes 1 kg of steam at 10 kg/cm² g from 60 °C feedwater?

2528 kJ/kg (604 kcal/kg): 526 kJ/kg to bring the water to boiling and 2002 kJ/kg to evaporate it.

How much coal for 10 t/h?

7.02 MW to the steam; at 80 % efficiency and 4000 kcal/kg, 1887 kg/h of coal: an evaporation ratio of 5.3 kg of steam per kg of coal.

Why is the feedwater enthalpy not just 4.187 × t?

That is close at low pressure. This calculator takes the water at the boiler pressure, which adds a few kJ/kg at high pressure.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.