Worked example
Example: Main at 10 bar(a), calorimeter 1.013 bar(a) at 120 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure in the main (absolute) | 10.000 bar |
| Pressure in the calorimeter after throttling (absolute) | 1.0132 bar |
| Temperature in the calorimeter | 120.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dryness fraction in the main | 96.989 % |
| Superheat in the calorimeter | 20.026 K |
| Steam enthalpy (constant through the throttle) | 2,716.5 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(h = h(p_2, T_2) \qquad x_1 = \frac{h - h_f(p_1)}{h_{fg}(p_1)} \qquad \Delta T_{sh} = T_2 - T_{sat}(p_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | main pressure | Pa |
| \(p_2\) | calorimeter pressure | Pa |
| \(T_2\) | calorimeter temperature | K |
| \(x_1\) | dryness in the main | – |
| \(\Delta T_{sh}\) | superheat in the calorimeter | K |
| \(h\) | steam enthalpy | J/kg |
| \(h_f, h_{fg}\) | saturated liquid enthalpy and latent heat at p₁ (IF97) | J/kg |
Method and standards
Throttling is isenthalpic; enthalpies from FireCAD's IAPWS-IF97.
Where it is used
- Steam quality checks at boiler outlet and users.
- Sterilisers and autoclaves needing dry steam.
- Training and laboratory tests.
Common mistakes
- Uninsulated calorimeter (heat loss reads as wetter steam).
- Sampling from the bottom of the pipe where water collects.
- Using gauge pressures.
Assumptions and limits
- Adiabatic throttling; representative sample.
- A result above 100 % dry means the main steam is superheated; no dryness is shown then.
- A calorimeter superheat below about 2 K is flagged: the thermometer error then dominates.
References
- Throttling at constant enthalpy
- IAPWS R7-97 IF97
Questions and answers
How does a throttling calorimeter measure dryness?
Steam from the main is throttled to near atmospheric pressure, where it becomes superheated; its enthalpy is unchanged, so the measured temperature gives the dryness. Steam at 10 bar(a) reaching 120 °C at 1.013 bar(a) was 97.0 % dry.
What if the calorimeter steam is not superheated?
The steam was too wet (below about 95 %); use a separating calorimeter before the throttle.
Why does dryness matter?
Wet steam carries less heat per kg, erodes valves and makes heat exchangers underperform.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.