Worked example
Example: 5 t/h condensate 10 bar g to 1 bar g, 90 % used. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condensate pressure before the trap | 10.000 bar g |
| Flash vessel pressure | 1.0000 bar g |
| Condensate flow | 5,000.0 kg/h |
| Share of the flash steam actually used | 90.000 % |
| Operating hours per year | 8,000.0 h |
| Cost of steam per tonne (your currency) | 2,500.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flash fraction | 12.534 % |
| Flash steam used | 564.02 kg/h |
| Latent heat recovered | 344.83 kW |
| Steam recovered per year | 4,512.1 t |
| Value per year (your currency) | 1.1280e+07 |
Open this example in the calculator and change any input.
Formula
\(x = \frac{h_{f1} - h_{f2}}{h_{fg2}} \qquad \dot m_{fs} = \dot m_c\,x\,u \qquad \dot Q = \dot m_{fs}\,h_{fg2} \qquad m_y = \dot m_{fs}\,t_y \qquad V_y = \frac{m_y}{1000\ \text{kg/t}}\,c_s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | condensate pressure (absolute in SI; shown and entered as gauge, bar g) | Pa |
| \(p_2\) | flash vessel pressure (absolute in SI; shown and entered as gauge) | Pa |
| \(\dot m_c\) | condensate flow | kg/s |
| \(u\) | share used | – |
| \(t_y\) | hours per year | s |
| \(c_s\) | cost of steam per tonne | currency |
| \(x\) | flash fraction | – |
| \(\dot m_{fs}\) | flash steam used | kg/s |
| \(\dot Q\) | latent heat recovered | W |
| \(m_y\) | steam per year | kg |
| \(V_y\) | value per year | currency |
| \(h_{f1}, h_{f2}, h_{fg2}\) | IF97 enthalpies | J/kg |
Method and standards
Isenthalpic flashing of saturated liquid, IAPWS-IF97 enthalpies.
Where it is used
- Condensate recovery schemes.
- Blowdown heat recovery.
- Deaerator steam reduction.
Common mistakes
- Counting flash steam that is vented.
- Using gauge pressure tables with absolute inputs.
- Ignoring the drop in condensate return temperature.
Assumptions and limits
- Saturated condensate at p_1; no subcooling.
- Pressures are shown as gauge and converted with the standard atmosphere (101.325 kPa); at altitude the gauge reading differs slightly.
- Each tonne of flash steam is valued as a tonne of boiler steam; where it replaces higher-pressure steam the value is a little high.
References
- IAPWS-IF97
Questions and answers
What is flash steam from 5 t/h of condensate at 10 bar g to 1 bar g worth?
12.5 % flashes; using 90 % of it gives 564 kg/h, 4512 t a year at 8000 h, worth 11.3 million at 2500 per tonne.
Why value it at boiler steam cost?
Each tonne used replaces a tonne the boiler would make; it is slightly generous where flash replaces higher-pressure steam.
Where can flash steam be used?
Deaerator heating, air heaters, low-pressure process heating.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.