Worked example
Example: HP heater 216 t/h, 180 bar(a), 200 to 240 °C, extraction 40 bar(a) / 350 °C, DCA 5.6 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feedwater flow | 216,000 kg/h |
| Feedwater pressure (absolute) | 180.00 bar |
| Feedwater inlet temperature | 200.00 °C |
| Feedwater outlet temperature | 240.00 °C |
| Extraction steam pressure at the heater (absolute) | 40.000 bar |
| Extraction steam condition | Superheated at the temperature below |
| Extraction steam temperature (superheated only) | 350.00 °C |
| Drain leaving the heater | Sub-cooled by a drain cooler (DCA) |
| Drain cooler approach | 5.6000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Extraction steam flow | 17,579 kg/h |
| Extraction per kg of feedwater | 8.1382 % |
| Heat duty | 10,815 kW |
| Shell saturation temperature | 250.36 °C |
| Terminal temperature difference | 10.358 K |
| Drain temperature | 205.60 °C |
| Feedwater inlet enthalpy | 859.47 kJ/kg |
| Feedwater outlet enthalpy | 1,039.7 kJ/kg |
| Extraction steam enthalpy | 3,093.3 kJ/kg |
| Drain enthalpy | 878.56 kJ/kg |
Open this example in the calculator and change any input.
Formula
Energy balance on a closed heater with no cascaded drains entering:
\(\dot Q = \dot m_{fw}\,(h_{fw,2} - h_{fw,1}) \qquad \dot m_e = \frac{\dot Q}{h_e - h_d}\)
\(TTD = T_{sat,e} - T_{fw,2} \qquad T_d = T_{fw,1} + DCA \;\;(\text{drain cooler}) \quad\text{or}\quad T_d = T_{sat,e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{fw}\) | feedwater flow | kg/s |
| \(p_{fw}\) | feedwater absolute pressure | Pa |
| \(T_{fw,1}\) | feedwater inlet temperature | K |
| \(T_{fw,2}\) | feedwater outlet temperature | K |
| \(p_e\) | extraction steam absolute pressure at the heater | Pa |
| \(\text{state}\) | dry saturated, or superheated at \(T_e\) | – |
| \(T_e\) | extraction steam temperature when superheated | K |
| \(\text{drain}\) | saturated drain, or drain cooler with \(DCA\) | – |
| \(DCA\) | drain cooler approach | K |
| \(\dot m_e\) | extraction steam flow | kg/s |
| \(\dot m_e / \dot m_{fw}\) | extraction per kg of feedwater | – |
| \(\dot Q\) | heat duty | W |
| \(T_{sat,e}\) | shell saturation temperature at \(p_e\) | K |
| \(TTD\) | terminal temperature difference | K |
| \(T_d\) | drain temperature | K |
| \(h_{fw,1}\) | feedwater inlet enthalpy | J/kg |
| \(h_{fw,2}\) | feedwater outlet enthalpy | J/kg |
| \(h_e\) | extraction steam enthalpy | J/kg |
| \(h_d\) | drain enthalpy | J/kg |
Method and standards
First-law balance with enthalpies from FireCAD's IAPWS-IF97 implementation; TTD and DCA as defined in the HEI Standards for Closed Feedwater Heaters.
Where it is used
- Heat balances of regenerative feed heating in power and cogeneration plants.
- Checking extraction flows against turbine heat balance diagrams.
- Estimating the effect of a heater taken out of service.
Common mistakes
- Using the extraction pressure at the turbine instead of at the heater shell (line losses).
- Forgetting drains cascaded from the next heater.
- Ignoring the heater's terminal temperature difference.
Assumptions and limits
- No drains cascaded in from a higher-pressure heater; for a heater that receives drains, subtract their heat from the duty first.
- No shell heat loss; the drain leaves at the extraction pressure.
- Pressure drop in the extraction line is included by entering the pressure at the heater.
- With dry saturated steam the feedwater must leave below the shell saturation temperature; with superheated steam it must leave below the steam temperature. A negative TTD (desuperheating zone) is allowed only with superheated steam.
- A warning appears when the drain cooler approach puts the drain above the feedwater outlet.
References
- IAPWS R7-97(2012) IF97
- HEI Standards for Closed Feedwater Heaters (terms)
Questions and answers
What are TTD and DCA?
The terminal temperature difference is the shell saturation temperature minus the feedwater outlet temperature. The drain cooler approach is the drain temperature minus the feedwater inlet temperature. Both are design figures of the heater.
How much extraction steam does an HP heater take?
For 60 kg/s of feedwater heated from 200 to 240 °C by steam at 40 bar(a) and 350 °C with a 5.6 K drain cooler approach, about 4.88 kg/s, or 8.1 % of the feedwater.
Can the TTD be negative?
Yes, with a desuperheating zone the feedwater can leave above the shell saturation temperature. The calculator allows it and warns, because it needs enough superheat in the extraction steam.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.