Steam Temperature Drop Along a Superheated Main

Temperature drop and remaining superheat of steam along a long main from the heat loss per metre, length and steam flow, and whether it starts to condense (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 5 t/h at 10 bar(a) / 220 °C, 150 W/m, 400 m1 t/h at 17.5 bar(a) / 260 °C, 120 W/m, 600 m20 t/h at 40 bar(a) / 400 °C, 250 W/m, 1000 m

From the pipe insulation heat-loss calculator.

Results

Steam temperature at the end201.69°C
Temperature drop18.315K
Superheat left at the end21.800K
Dryness at the end (1 = still superheated)100.00%
Total heat lost60.000kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t/h at 10 bar(a) / 220 °C, 150 W/m, 400 m. The inputs, in the units selected above:

InputValue
Steam flow5,000.0 kg/h
Heat loss per metre of pipe150.00 W/m
Length of the main400.00 m
Steam pressure (absolute)10.000 bar
Steam temperature at the start220.00 °C

Applying the formula below gives:

ResultValue
Steam temperature at the end201.69 °C
Temperature drop18.315 K
Superheat left at the end21.800 K
Dryness at the end (1 = still superheated)100.00 %
Total heat lost60.000 kW

Open this example in the calculator and change any input.

Formula

\(h_2 = h_1 - \frac{q'\,L}{\dot m} \qquad T_2 = T(p, h_2) \qquad \Delta T_{sh} = T_2 - T_{sat}(p)\)

Variables

Symbol Meaning SI unit
\(\dot m\) steam flow kg/s
\(q'\) heat loss per metre W/m
\(L\) length m
\(p\) steam pressure Pa
\(T_1\) temperature at the start K
\(T_2\) temperature at the end K
\(\Delta T\) temperature drop K
\(\Delta T_{sh}\) superheat left K
\(x_2\) dryness at the end –
\(\dot Q\) total heat lost W
\(h_1, h_2\) enthalpies (IF97) J/kg

Method and standards

Energy balance of the steam with constant pressure; state at the end from FireCAD's IAPWS-IF97.

Where it is used

  • Long steam mains in process plants and refineries.
  • Checking insulation effectiveness.
  • Planning drip legs and traps.

Common mistakes

  • Using design flow when the main runs at low flow.
  • Ignoring pressure drop, which also changes saturation temperature.
  • Using bare-pipe loss for insulated pipe or the reverse.

Assumptions and limits

  • Constant pressure along the main; uniform heat loss.
  • A warning is given when the steam turns wet, and another when it condenses completely (the end state is then liquid, and the superheat and dryness are not shown).
  • The heat loss per metre is held constant although the steam cools along the main.

References

  • Energy balance of the steam
  • IAPWS R7-97 IF97

Questions and answers

How much does steam cool along a main?

5 t/h at 10 bar(a) and 220 °C losing 150 W/m over 400 m drops 18 K to 202 °C, keeping 22 K of superheat.

Why keep superheat at the far end?

Dry steam needs no drip traps along the main and arrives without condensate; once superheat is gone, condensate forms.

Does low flow make it worse?

Yes: the heat loss is the same, so less steam cools more; mains often lose their superheat at night load.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.