Worked example
Example: 5 t/h at 10 bar(a) / 220 °C, 150 W/m, 400 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 5,000.0 kg/h |
| Heat loss per metre of pipe | 150.00 W/m |
| Length of the main | 400.00 m |
| Steam pressure (absolute) | 10.000 bar |
| Steam temperature at the start | 220.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam temperature at the end | 201.69 °C |
| Temperature drop | 18.315 K |
| Superheat left at the end | 21.800 K |
| Dryness at the end (1 = still superheated) | 100.00 % |
| Total heat lost | 60.000 kW |
Open this example in the calculator and change any input.
Formula
\(h_2 = h_1 - \frac{q'\,L}{\dot m} \qquad T_2 = T(p, h_2) \qquad \Delta T_{sh} = T_2 - T_{sat}(p)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | steam flow | kg/s |
| \(q'\) | heat loss per metre | W/m |
| \(L\) | length | m |
| \(p\) | steam pressure | Pa |
| \(T_1\) | temperature at the start | K |
| \(T_2\) | temperature at the end | K |
| \(\Delta T\) | temperature drop | K |
| \(\Delta T_{sh}\) | superheat left | K |
| \(x_2\) | dryness at the end | – |
| \(\dot Q\) | total heat lost | W |
| \(h_1, h_2\) | enthalpies (IF97) | J/kg |
Method and standards
Energy balance of the steam with constant pressure; state at the end from FireCAD's IAPWS-IF97.
Where it is used
- Long steam mains in process plants and refineries.
- Checking insulation effectiveness.
- Planning drip legs and traps.
Common mistakes
- Using design flow when the main runs at low flow.
- Ignoring pressure drop, which also changes saturation temperature.
- Using bare-pipe loss for insulated pipe or the reverse.
Assumptions and limits
- Constant pressure along the main; uniform heat loss.
- A warning is given when the steam turns wet, and another when it condenses completely (the end state is then liquid, and the superheat and dryness are not shown).
- The heat loss per metre is held constant although the steam cools along the main.
References
- Energy balance of the steam
- IAPWS R7-97 IF97
Questions and answers
How much does steam cool along a main?
5 t/h at 10 bar(a) and 220 °C losing 150 W/m over 400 m drops 18 K to 202 °C, keeping 22 K of superheat.
Why keep superheat at the far end?
Dry steam needs no drip traps along the main and arrives without condensate; once superheat is gone, condensate forms.
Does low flow make it worse?
Yes: the heat loss is the same, so less steam cools more; mains often lose their superheat at night load.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.