Flash Steam from Condensate or Blowdown

Fraction and flow of flash steam released when saturated condensate or boiler blowdown drops to a lower pressure, from IAPWS-IF97 enthalpies.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Flash vessel and condensateBoiler attendant and boiler operator examinationsBoiler operation engineer (BOE) examinations

Inputs

Examples: Blowdown 40 bar to deaerator 2 barTrap 10 bar to atmosphereHP trap 60 bar to 5 bar flash vessel

Pressure of the saturated condensate or blowdown before the valve.
Pressure in the flash vessel or return line.

Results

Flash steam fraction26.470%
Flash steam flow661.74kg/h
Remaining condensate flow1,838.3kg/h
Upstream saturation temperature250.36°C
Flash temperature120.21°C
Upstream liquid enthalpy1,087.4kJ/kg
Liquid enthalpy at flash pressure504.68kJ/kg
Latent heat at flash pressure2,201.6kJ/kg
Heat carried by the flash steam404.68kW
Flash steam volume flow586.13m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Blowdown 40 bar to deaerator 2 bar. The inputs, in the units selected above:

InputValue
Upstream pressure (absolute)40.000 bar
Flash pressure (absolute)2.0000 bar
Condensate or blowdown flow2,500.0 kg/h

Applying the formula below gives:

ResultValue
Flash steam fraction26.470 %
Flash steam flow661.74 kg/h
Remaining condensate flow1,838.3 kg/h
Upstream saturation temperature250.36 °C
Flash temperature120.21 °C
Upstream liquid enthalpy1,087.4 kJ/kg
Liquid enthalpy at flash pressure504.68 kJ/kg
Latent heat at flash pressure2,201.6 kJ/kg
Heat carried by the flash steam404.68 kW
Flash steam volume flow586.13 m³/h

Open this example in the calculator and change any input.

Formula

An energy balance across the pressure drop (an isenthalpic throttling to the flash pressure):

\(x = \frac{h_{f1} - h_{f2}}{h_{fg2}} \qquad \dot m_{fs} = x\,\dot m \qquad \dot m_c = (1 - x)\,\dot m \qquad \dot Q_{fs} = \dot m_{fs}\,h_{fg2} \qquad \dot V_{fs} = \dot m_{fs}\,v_{g2}\)

Variables

Symbol Meaning SI unit
\(p_1\) upstream absolute pressure of the saturated liquid Pa
\(p_2\) absolute pressure after the drop (flash vessel) Pa
\(\dot m\) liquid mass flow before the drop kg/s
\(x\) mass fraction flashed to steam –
\(\dot m_{fs}\) flash steam mass flow kg/s
\(\dot m_{c}\) remaining condensate mass flow kg/s
\(T_1\), \(T_2\) saturation temperatures at \(p_1\) and \(p_2\) K
\(h_{f1}\) saturated liquid enthalpy at \(p_1\) J/kg
\(h_{f2}\) saturated liquid enthalpy at \(p_2\) J/kg
\(h_{fg2}\) latent heat of vaporisation at \(p_2\) J/kg
\(\dot Q_{fs}\) latent heat carried by the flash steam W
\(\dot V_{fs}\) volume flow of the flash steam at \(p_2\) m³/s

Method and standards

Enthalpies from FireCAD's IAPWS-IF97 implementation on the saturation line (region 1 liquid and region 2 vapour, region 3 above about 165 bar, region 4 pressure–temperature relation). The throttling is treated as adiabatic with no kinetic energy change, the usual assumption for flash vessels and condensate receivers.

Where it is used

  • Sizing flash vessels for blowdown and condensate.
  • Valuing flash steam recovery to a low-pressure header or deaerator.
  • Sizing condensate return lines, which carry the flash steam as well as water.

Common mistakes

  • Using gauge pressures in the flash fraction instead of absolute.
  • Assuming the condensate is saturated when it is subcooled after a trap or a cooler: it flashes less.
  • Sizing condensate lines for water only; the flash steam takes most of the volume.

Assumptions and limits

  • Saturated liquid upstream; sub-cooled liquid flashes less.
  • Equilibrium at the flash pressure; real vessels carry over a little liquid.
  • Both pressures absolute and below the critical pressure (220.64 bar).

References

  • IAPWS R7-97(2012) IF97

Questions and answers

Why does condensate flash at all?

Saturated water at 40 bar holds 1 087 kJ/kg. At 2 bar liquid water can hold only 505 kJ/kg, so the surplus 582 kJ/kg evaporates about 26 % of the mass into steam at 2 bar.

What if the condensate is sub-cooled before the valve?

Use the actual liquid enthalpy instead of h_f1. The calculator assumes saturated liquid upstream, which is the case for steam traps and continuous blowdown; sub-cooling reduces the flash fraction.

What is the flash steam worth?

The heat shown as "heat carried by the flash steam" is the latent heat you recover if the flash steam is used, for example in a deaerator. For 2 500 kg/h of 40 bar blowdown to 2 bar it is about 400 kW.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators