Worked example
Example: 100 m³, 90 % water, 16 to 6 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Accumulator volume | 100.00 m³ |
| Water filling at charge, share of volume | 90.000 % |
| Charging pressure (absolute) | 16.000 bar |
| Discharge (minimum) pressure (absolute) | 6.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam released | 6,936.3 kg |
| Steam released per m³ of accumulator volume | 69.363 kg/m³ |
| Water held at charge | 77.675 t |
| Share of the charged water released as steam | 8.9299 % |
Open this example in the calculator and change any input.
Formula
\(m_w = \phi\,V\,\rho_f(p_1) \qquad \frac{dm}{m} = \frac{dh_f}{h_{fg}} \qquad x = 1 - \exp\left(-\int_{T_2}^{T_1} \frac{dh_f}{h_{fg}}\right) \qquad m_s = m_w\,x\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | accumulator volume | m³ |
| \(\phi\) | water filling at charge | – |
| \(p_1\) | charging pressure | Pa |
| \(p_2\) | discharge pressure | Pa |
| \(m_s\) | steam released | kg |
| \(m_s/V\) | steam released per m³ of accumulator volume (not a density) | kg/m³ |
| \(m_w\) | water at charge | kg |
| \(x\) | share of the charged water released as steam | – |
| \(m\) | water left in the vessel during discharge | kg |
| \(T_1\), \(T_2\) | saturation temperatures at \(p_1\) and \(p_2\) | K |
| \(\rho_f\) | saturated water density (IF97) | kg/m³ |
| \(h_f, h_{fg}\) | saturated liquid enthalpy and latent heat (IF97) | J/kg |
Method and standards
Saturated water flashing as the pressure falls from charging to discharge pressure (Ruths principle). The steam leaves as it forms, so the energy balance of the water left, d(m h_f) = h_g dm, gives dm/m = dh_f/h_fg; it is integrated over the saturation temperature with FireCAD's IAPWS-IF97.
Where it is used
- Peak-load steam supply in process plants.
- Smoothing boiler firing for batch users.
- Storing excess steam from waste heat.
Common mistakes
- Using the whole vessel volume as water.
- Ignoring the steam space needed for swelling during charging.
- Forgetting that the outlet needs a pressure reducing valve.
Assumptions and limits
- Water saturated at charging pressure; no heat loss; steam leaves dry.
- Gradual discharge with the steam leaving as it forms; this gives about 1 % less than a single-step flash of the whole charge at the discharge pressure. The steam already in the steam space at charge is not counted.
- The filling is the share at charge (after the water has swelled); leave steam space above it for separation.
References
- Flash of saturated water between two pressures (Ruths principle)
- IAPWS R7-97 IF97
Questions and answers
How much steam does an accumulator store?
A 100 m³ accumulator 90 % full of water charged to 16 bar(a) and drawn down to 6 bar(a) releases 6.9 t of steam, 69 kg per m³: 8.9 % of the 77.7 t of water.
Why use one?
It supplies short peaks (autoclaves, batch processes, soot blowers) so the boiler can fire steadily.
How do I get more storage?
A wider pressure swing: charge higher or let the users accept a lower minimum pressure.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.