Worked example
Example: Process deaerator 0.2 bar g, 50 t/h, water 80 °C, steam 3 bar(a) saturated. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Deaerated feedwater outlet flow | 50,000 kg/h |
| Deaerator pressure (absolute) | 1.2132 bar |
| Vent steam flow | 0 kg/h |
| Inlet water temperature (condensate and make-up, mixed) | 80.000 °C |
| Heating steam pressure (absolute) | 3.0000 bar |
| Heating steam condition | Dry saturated |
| Heating steam temperature (superheated only) | 250.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heating steam flow | 2,210.0 kg/h |
| Inlet water flow | 47,790 kg/h |
| Steam per kg of feedwater | 4.4200 % |
| Deaerator (saturation) temperature | 105.10 °C |
| Inlet water enthalpy | 335.01 kJ/kg |
| Heating steam enthalpy | 2,724.9 kJ/kg |
| Outlet feedwater enthalpy (saturated liquid) | 440.64 kJ/kg |
| Vent steam enthalpy (saturated vapour) | 2,683.5 kJ/kg |
Open this example in the calculator and change any input.
Formula
Mass and energy balances on the deaerator, outlet saturated liquid and vent saturated vapour at \(p_d\):
\(\dot m_w + \dot m_s = \dot m_{out} + \dot m_v\)
\(\dot m_w h_w + \dot m_s h_s = \dot m_{out} h_{f,d} + \dot m_v h_{g,d}\)
\(\dot m_s = \frac{\dot m_{out}\,(h_{f,d} - h_w) + \dot m_v\,(h_{g,d} - h_w)}{h_s - h_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{out}\) | deaerated feedwater outlet flow | kg/s |
| \(p_d\) | deaerator absolute pressure | Pa |
| \(\dot m_v\) | vent steam flow | kg/s |
| \(T_w\) | mixed inlet water temperature | K |
| \(p_s\) | heating steam absolute pressure | Pa |
| \(\text{state}\) | dry saturated, or superheated at \(T_s\) | – |
| \(T_s\) | heating steam temperature when superheated | K |
| \(\dot m_s\) | heating steam flow | kg/s |
| \(\dot m_w\) | inlet water flow | kg/s |
| \(\dot m_s / \dot m_{out}\) | steam per kg of feedwater | – |
| \(T_d\) | deaerator saturation temperature | K |
| \(h_w\) | inlet water enthalpy | J/kg |
| \(h_s\) | heating steam enthalpy | J/kg |
| \(h_{f,d}\) | saturated liquid enthalpy at \(p_d\) | J/kg |
| \(h_{g,d}\) | saturated vapour enthalpy at \(p_d\) | J/kg |
Method and standards
First-law balance on a direct-contact heater, enthalpies from FireCAD's IAPWS-IF97 implementation. Steam throttled from \(p_s\) to \(p_d\) keeps its enthalpy.
Where it is used
- Sizing deaerator heating steam and the pegging steam line.
- Heat balances of feedwater systems with condensate return.
- Checking deaerator pressure control at part load.
Common mistakes
- Forgetting the vent steam.
- Using cold make-up temperature when the make-up is preheated by blowdown or flash recovery.
- Ignoring hot condensate return, which can make the deaerator need almost no steam.
Assumptions and limits
- No heat loss from the deaerator shell.
- Inlet streams (condensate, make-up, flash steam returns) are entered as one mixed water stream; add other steam inputs to the heating steam or work them out separately.
- Outlet water leaves saturated at deaerator pressure.
- The inlet water enthalpy is taken at the deaerator pressure, not its own line pressure; for liquid water the difference is negligible.
- The heating steam pressure must be at least the deaerator pressure.
References
- IAPWS R7-97(2012) IF97
Questions and answers
How much steam does a deaerator use?
For 50 t/h of feedwater at 0.2 bar g (105.1 °C) from water at 80 °C, with dry saturated steam at 3 bar(a), about 0.614 kg/s (2.2 t/h), or 4.4 % of the outlet flow.
Why include the vent?
The vent releases non-condensable gases with a little steam. That steam leaves as saturated vapour at deaerator pressure and must be supplied too; the deaerator maker gives the vent rate; it is small, a fraction of a per cent of the outlet flow.
What if the inlet water is already hot?
If the mixed inlet is at or above the deaerator saturation temperature, no heating steam is needed and the water flashes instead; the calculator stops with a message.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.