Worked example
Example: Paper 10 t/h wet at 55 % moisture to 8 %, 60 % efficiency, 4 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet product feed | 10,000 kg/h |
| Moisture in, wet basis | 55.000 % |
| Moisture out, wet basis | 8.0000 % |
| Product (water) temperature in | 50.000 °C |
| Evaporation temperature (wet-bulb or boiling) | 80.000 °C |
| Dryer thermal efficiency | 60.000 % |
| Heating steam pressure (absolute, saturated) | 4.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam consumption | 9,712.9 kg/h |
| Water evaporated | 5,108.7 kg/h |
| Steam per kg of water evaporated | 1.9013 kg/kg |
| Heat supplied | 5,755.8 kW |
Open this example in the calculator and change any input.
Formula
\(\dot W = \dot m_1 - \dot m_1\frac{1 - x_1}{1 - x_2} \qquad \dot Q = \frac{\dot W\,[h_g(T_{ev}) - h_l(T_1)]}{\eta_d} \qquad \dot m_s = \frac{\dot Q}{h_{fg}(p_s)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_1\) | wet feed | kg/s |
| \(x_1\) | moisture in, wet basis | – |
| \(x_2\) | moisture out, wet basis | – |
| \(T_1\) | water temperature in; \(h_l(T_1)\) is taken at 101.325 kPa | K |
| \(T_{ev}\) | evaporation temperature | K |
| \(\eta_d\) | dryer thermal efficiency | – |
| \(p_s\) | steam pressure | Pa |
| \(\dot m_s\) | steam consumption | kg/s |
| \(\dot W\) | water evaporated | kg/s |
| \(\dot m_s/\dot W\) | steam per kg water | kg/kg |
| \(\dot Q\) | heat supplied | W |
| \(h_g, h_l, h_{fg}\) | water and steam enthalpies (IF97) | J/kg |
Method and standards
Solids balance for the water removed; heat to warm and evaporate it divided by a dryer efficiency; steam latent heat from FireCAD's IAPWS-IF97.
Where it is used
- Steam budgets of paper machines, textile stenters and food dryers.
- Comparing dryer performance.
- Sizing steam supply and condensate systems.
Common mistakes
- Mixing wet-basis and dry-basis moisture.
- Using an efficiency from another dryer type.
- Ignoring the product's own sensible heat.
Assumptions and limits
- Steady operation; efficiency covers air, product and losses. The sensible heat of the dry solids is not calculated separately; it is inside the efficiency.
- The steam gives up only its latent heat: the condensate leaves saturated at the steam pressure, and flash or condensate heat recovery is not credited.
- The water in the feed is liquid at atmospheric pressure, so its temperature in must be below 100 °C.
References
- Solids and energy balance
- IAPWS R7-97 IF97
Questions and answers
How much steam does a dryer use?
10 t/h of wet paper at 55 % moisture dried to 8 % evaporates 5.1 t/h of water; at 60 % dryer efficiency with 4 bar(a) steam it uses 9.7 t/h of steam, 1.9 kg per kg of water.
Why more than 1 kg of steam per kg of water?
Besides evaporating the water the steam heats air, product and losses; the efficiency covers them.
How do I cut it?
Press out more water mechanically first, recover exhaust air heat, and keep condensate drainage good so the dryer surface stays hot.