Worked example
Example: 20 t/h, 5 % blowdown, 60 % condensate return, 2 % losses. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam generated | 20,000 kg/h |
| Blowdown, as a share of steam | 5.0000 % |
| Condensate returned, as a share of the steam reaching the users | 60.000 % |
| Other losses, as a share of steam (vents, traps, leaks, soot blowing) | 2.0000 % |
| Make-up water density (for the daily volume) | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Make-up water flow | 9,240.0 kg/h |
| Make-up as a share of feed water | 44.000 % |
| Make-up water per day | 222.20 m³ |
| Feed water flow | 21,000 kg/h |
| Condensate returned | 11,760 kg/h |
| Blowdown | 1,000.0 kg/h |
Open this example in the calculator and change any input.
Formula
\(B = b\,S \qquad C = r\,S\,(1 - l) \qquad F = S + B \qquad M = F - C = B + l\,S + (1 - r)(1 - l)\,S \qquad V_d = \frac{M \cdot 86\,400\ \text{s}}{\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | steam generated | kg/s |
| \(b\) | blowdown as a share of steam | – |
| \(r\) | condensate returned as a share of the steam reaching the users, \(S(1 - l)\) | – |
| \(l\) | other losses as a share of steam | – |
| \(\rho\) | make-up water density | kg/m³ |
| \(M\) | make-up water flow | kg/s |
| \(M/F\) | make-up as a share of feed water | – |
| \(V_d\) | make-up water per day | m³ |
| \(F\) | feed water flow | kg/s |
| \(C\) | condensate returned | kg/s |
| \(B\) | blowdown | kg/s |
Method and standards
Steady-state mass balance on the feed water system: water leaves as steam that is not returned, as blowdown and as losses; make-up replaces it.
Where it is used
- Sizing water treatment plants and make-up pumps.
- Water budgets for boiler houses.
- Checking condensate return performance.
Common mistakes
- Forgetting blowdown, vent and soot-blowing losses.
- Counting returned condensate twice.
- Using design condensate return where actual return is lower.
Assumptions and limits
- Deaerator heating steam is taken from the boiler's own steam and returns in the feed water, so it does not change the make-up.
- Blowdown and other losses are shares of all the steam generated, deaerator steam included. The losses leave on the steam side, so the users receive \(S(1 - l)\) and the condensate return is a share of that.
- Steady state; storage changes are ignored.
- Water treatment plant losses (regeneration, reject) are upstream of the make-up and not included.
References
- Mass balance on the feed water system
Questions and answers
How much make-up water does a boiler need?
Make-up = blowdown + other losses + condensate not returned, which equals feed water − condensate returned. A 20 t/h boiler with 5 % blowdown, 2 % losses and 60 % condensate return needs 9.24 t/h of make-up, 44 % of its feed water.
Why does a power plant need so little?
Nearly all its steam returns as condensate. With 97 % return, 1 % blowdown and 0.5 % other losses, a 300 t/h unit needs about 13.5 t/h.
What are the other losses?
Deaerator vents, trap and drain losses, leaks, soot-blowing and atomising steam, sampling. Enter them as a share of steam.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.