Worked example
Example: 10 t/h water 30 to 80 °C, 4 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Product flow | 10,000 kg/h |
| Product specific heat | 4.1868 kJ/(kg·K) |
| Product in | 30.000 °C |
| Product out | 80.000 °C |
| Steam pressure (absolute) | 4.0000 bar |
| Steam dryness fraction | 97.000 % |
| Condensate leaving temperature | 90.000 °C |
| Heat losses (share of useful heat) | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat supplied, product heat plus losses | 610.58 kW |
| Heat given up per kg of steam | 2,296.8 kJ/kg |
| Steam consumption | 957.00 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_p c_p (T_2 - T_1)(1 + k_l), \quad \dot m_s = \frac{\dot Q}{h_{steam}(p, x) - h_{cond}(p, T_c)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_p\) | Product flow | kg/s |
| \(c_p\) | Product specific heat | J/(kg·K) |
| \(T_1\) | Product in | K |
| \(T_2\) | Product out | K |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(x\) | Steam dryness fraction | - |
| \(T_c\) | Condensate leaving temperature | K |
| \(k_l\) | Heat losses (share of useful heat) | - |
| \(\dot Q\) | Heat supplied, product heat plus losses | W |
| \(\Delta h\) | Heat given up per kg of steam | J/kg |
| \(\dot m_s\) | Steam consumption | kg/s |
Method and standards
Energy balance.
Where it is used
- Heat exchangers, jacketed vessels, process heaters.
- BOE examinations.
Common mistakes
- Latent heat only.
- Forgetting losses.
Assumptions and limits
- Steady flow.
- Steam is wet or dry saturated at p_s (dryness x); superheated steam is not an option here (see the steam consumption from heat duty calculator).
- The heat shown includes the loss allowance; the heat reaching the product is Q/(1 + k_l).
- Condensate leaves between the product inlet temperature and the steam saturation temperature.
References
- Energy balance ṁ_s = ṁ_p c_p ΔT (1 + k)/(h_steam − h_condensate); IAPWS-IF97
Questions and answers
10 t/h of water from 30 to 80 °C with 4 bar(a) steam?
About 610 kW with 5 % losses: roughly 950 kg/h of steam.
Why does condensate temperature matter?
Sub-cooling the condensate gives extra heat per kg.
Wet steam?
Lower dryness carries less latent heat; separators help.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.