Worked example
Example: 10 bar g, dryness 0.9. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam pressure (absolute) | 11.013 bar |
| What you know besides the pressure | Dryness fraction |
| Dryness fraction (when given) | 90.000 % |
| Enthalpy of the wet steam (when given) | 0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature | 184.12 °C |
| Dryness fraction | 90.000 % |
| Enthalpy h = h_f + x h_fg | 2,580.8 kJ/kg |
| Entropy s = s_f + x s_fg | 6.1143 kJ/(kg·K) |
| Specific volume v = v_f + x (v_g − v_f) | 0.15962 m³/kg |
| Internal energy u = h − p v | 2,405.0 kJ/kg |
| Enthalpy of saturated water | 781.43 kJ/kg |
| Latent heat of evaporation | 1,999.3 kJ/kg |
| Enthalpy of dry saturated steam | 2,780.7 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(h = h_f + x\, h_{fg}, \quad s = s_f + x\, s_{fg}\)
\(v = v_f + x\,(v_g - v_f), \quad u = h - p\, v\)
\(x = \frac{h - h_f}{h_{fg}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Steam pressure (absolute) | Pa |
| \(\text{given}\) | What you know besides the pressure | - |
| \(x\) | Dryness fraction (when given) | - |
| \(h_{given}\) | Enthalpy of the wet steam (when given) | J/kg |
| \(T_s\) | Saturation temperature | K |
| \(h\) | Enthalpy h = h_f + x h_fg | J/kg |
| \(s\) | Entropy s = s_f + x s_fg | J/(kg·K) |
| \(v\) | Specific volume v = v_f + x (v_g − v_f) | m³/kg |
| \(u\) | Internal energy u = h − p v | J/kg |
| \(h_f\) | Enthalpy of saturated water | J/kg |
| \(h_{fg}\) | Latent heat of evaporation | J/kg |
| \(h_g\) | Enthalpy of dry saturated steam | J/kg |
Method and standards
Saturated water and dry saturated steam properties at the pressure come from IAPWS-IF97; wet steam is the mass-weighted mix of the two phases.
Worked example
Steam at 10 bar g (11.013 bar absolute) has a dryness fraction of 0.9. From the steam tables at 11.013 bar: h_f = 781.4 kJ/kg, h_fg = 1999.3 kJ/kg, v_g = 0.1772 m³/kg.
- h = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg
- v ≈ x v_g = 0.9 × 0.1772 = 0.1595 m³/kg (0.1596 with the water volume added)
- Saturation temperature 184.1 °C
Where it is used
- Boiler attendant and operator examinations: steam table questions.
- Heat content of wet steam from a boiler or a long main.
- Checking a calorimeter result.
Common mistakes
- Using gauge pressure in the steam tables, which are in absolute pressure.
- Applying the dryness fraction to the whole enthalpy (x h_g) instead of to the latent heat only.
- Using v = x v_g and forgetting the small water volume at high pressure.
Assumptions and limits
- Wet steam only (dryness 0 to 1).
- Equilibrium properties; no superheat.
References
- IAPWS-IF97 (water and steam)
Questions and answers
What is the enthalpy of steam at 10 bar g with dryness 0.9?
The steam boils at 184.1 °C. h = h_f + x h_fg = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg, and the specific volume is 0.160 m³/kg.
What does dryness fraction mean?
The mass of dry steam in each kg of wet steam. Dryness 0.9 means 0.9 kg of steam and 0.1 kg of water droplets.
Can I find the dryness from the enthalpy?
Yes, choose enthalpy as the known value: x = (h − h_f)/h_fg. An enthalpy above that of dry saturated steam means the steam is superheated, not wet, and the page says so instead of giving a dryness.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.