Worked example
Example: Fuel oil No. 6, GCV entered 42.5 MJ/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon | 85.500 % |
| Hydrogen | 11.500 % |
| Oxygen | 0.70000 % |
| Nitrogen | 0.20000 % |
| Sulphur | 2.0000 % |
| Ash | 0.10000 % |
| Moisture | 0 % |
| Gross calorific value, as fired (0 = estimate) | 42,500 kJ/kg |
| Excess air | 15.000 % |
| Air humidity (kg water per kg dry air) | 0.013000 kg/kg |
| Combustion air temperature entering the boiler | 30.000 °C |
| Flue gas temperature leaving the boiler (after air heater) | 160.00 °C |
| CO in dry flue gas | 50.000 ppm |
| Unburned carbon in residue, per kg fuel | 0 % |
| Temperature at which ash leaves | 25.000 °C |
| Surface radiation and convection loss | 0.50000 % |
| Unaccounted loss / manufacturer's margin | 0.50000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross calorific value used | 42,500 kJ/kg |
| Net calorific value | 39,991 kJ/kg |
| Dry gas loss | 5.0717 % |
| Water from hydrogen in fuel | 6.5227 % |
| Moisture in fuel | 0 % |
| Moisture in air | 0.12412 % |
| Unburned CO | 0.040598 % |
| Unburned carbon in residue | 0 % |
| Sensible heat in residue | 0 % |
| Surface radiation and convection | 0.50000 % |
| Unaccounted | 0.50000 % |
| Total losses | 12.759 % |
| Credit: entering dry air above 25 °C | 0.18818 % |
| Credit: moisture in entering air | 0.004541 % |
| Total credits | 0.19273 % |
| Fuel efficiency, gross (HHV) basis | 87.434 % |
| Efficiency, net (LHV) basis | 92.920 % |
Open this example in the calculator and change any input.
Formula
Losses per kg fuel, each then divided by the gross calorific value:
\(L_{dg} = m_{g,dry}\left[h_{g}(T_g) - h_{g}(T_{ref})\right] \qquad L_{H} = m_{H_2O,H}\left[h_v(T_g) - h_f(T_{ref})\right] \qquad L_{M} = M\left[h_v(T_g) - h_f(T_{ref})\right]\)
\(L_{\omega} = \omega\,m_a\left[h_v(T_g) - h_v(T_{ref})\right] \qquad L_{CO} = y_{CO}\,\frac{m_{g,dry}}{M_{g,dry}}\,M_{CO}\,\Delta h_{CO} \qquad L_{ub} = C_{ub}\,\Delta h_{C} \qquad L_{r} = (A + C_{ub})\,c_{p,r}\,(T_r - T_{ref})\)
Credits for heat entering above the reference temperature:
\(B_{a} = m_a\left[h_{air}(T_a) - h_{air}(T_{ref})\right] \qquad B_{\omega} = \omega\,m_a\left[h_v(T_a) - h_v(T_{ref})\right]\)
\(\eta_{GCV} = 1 - \frac{\sum L}{GCV} + \frac{\sum B}{GCV} \qquad \eta_{NCV} = \eta_{GCV}\,\frac{GCV}{NCV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\), \(H\), \(O\), \(N\), \(S\), \(A\), \(M\) | ultimate analysis as fired, mass fractions | – |
| \(GCV_{in}\) | gross calorific value entered (0 = estimate by Channiwala–Parikh) | J/kg |
| \(EA\) | excess air fraction | – |
| \(\omega\) | air humidity, kg water per kg dry air | kg/kg |
| \(T_a\) | combustion air temperature entering the boiler boundary | K |
| \(T_g\) | flue gas temperature leaving the boundary (after the air heater) | K |
| \(T_{ref}\) | reference temperature, 298.15 K (25 °C) | K |
| \(y_{CO}\) | CO in dry flue gas, volume fraction | – |
| \(C_{ub}\) | unburned carbon in residue per kg fuel | kg/kg |
| \(T_r\) | temperature at which residue (ash) leaves | K |
| \(m_a\), \(m_{g,dry}\) | actual dry air and dry flue gas per kg fuel (from the combustion balance) | kg/kg |
| \(m_{H_2O,H}\) | water formed from hydrogen per kg fuel | kg/kg |
| \(M_{g,dry}\), \(M_{CO}\) | molar mass of dry flue gas and of CO | kg/kmol |
| \(h_g\), \(h_{air}\) | enthalpy of dry flue gas and of air (Shomate integration) | J/kg |
| \(h_v\) | enthalpy of water vapour: IF97 at 1 psia for the water from fuel hydrogen and moisture; ideal-gas (Shomate) H₂O for the moisture in air | J/kg |
| \(h_f\) | enthalpy of liquid water at 25 °C (IF97) | J/kg |
| \(\Delta h_{CO}\) | heat of burning CO to CO₂, 10 160 Btu/lb = 23.63 MJ/kg | J/kg |
| \(\Delta h_{C}\) | heat of burning carbon to CO₂, 14 500 Btu/lb = 33.73 MJ/kg | J/kg |
| \(c_{p,r}\) | mean specific heat of residue, 0.2 Btu/(lb·°F) = 837 J/(kg·K) | J/(kg·K) |
| \(GCV\), \(NCV\) | gross and net calorific value used | J/kg |
| \(L_{dg}\), \(L_{H}\), \(L_{M}\), \(L_{\omega}\), \(L_{CO}\), \(L_{ub}\), \(L_{r}\) | losses: dry gas, water from hydrogen, fuel moisture, air moisture, CO, unburned carbon, residue | – |
| \(L_{rc}\), \(L_{un}\) | radiation and convection, unaccounted (entered as fractions of input) | – |
| \(\sum L\), \(\sum B\) | total losses and total credits, fractions of GCV | – |
| \(B_{a}\), \(B_{\omega}\) | credits for entering dry air and its moisture | – |
| \(\eta_{GCV}\), \(\eta_{NCV}\) | efficiency on the gross and on the net basis | – |
Method and standards
The energy balance (indirect) method of ASME PTC 4-2013 (owner decision 2026-11-09): losses and credits referred to 25 °C on the gross calorific value. The combustion balance is the same as in the combustion calculator (exact molar ratios, PTC 4 air). Gas enthalpies are integrated from NIST Shomate heat capacities of the actual flue gas composition rather than taken from a fixed 1.005 kJ/(kg·K); water vapour enthalpy for the water from the fuel comes from IF97 at 1 psia as PTC 4 §5.19.5 specifies; the moisture entering with the air stays vapour throughout, so its loss and credit use the ideal-gas (Shomate) H₂O enthalpy. Radiation and unaccounted losses are entered, as the standard measures or agrees them.
Where it is used
- Acceptance and performance tests of new boilers against the maker's guarantee.
- Energy audits of coal, biomass and oil-fired boilers (BEE, India), where the loss list shows what to fix.
- Comparing fuels: high-moisture biomass or lignite against coal on the same boiler.
- Tracking efficiency over time from routine O₂, gas temperature and ash carbon readings.
Common mistakes
- Mixing GCV and NCV: efficiency on NCV is several points higher, and quotations often do not say which.
- Using a fuel analysis on the air-dried basis when the fuel is fired with more moisture.
- Reading O₂ and gas temperature after the air heater or after leakage, not at the boundary used for the test.
- Taking the radiation loss as a fixed 2 % for every size of boiler.
Assumptions and limits
- Steady state, single fuel, no flue gas recirculation or sorbent; fuel sensible heat credit is not included.
- Excess air is an input. To find it from a measured O₂ reading, use the excess air from O₂ calculator first.
- The air is the excess air entered on the full fuel analysis. As in PTC 4, the dry gas is built from the carbon burned: unburned carbon forms no CO₂ and leaves its oxygen in the gas, and the measured CO replaces CO₂ and leaves half its oxygen.
- The flue gas temperature must be above about 39 °C (saturation at 1 psia) and above the entering air temperature.
- Residue sensible heat uses a mean specific heat of 0.2 Btu/(lb·°F) for coal and biomass ash instead of the PTC 4 temperature curve.
References
- ASME PTC 4-2013 Fired Steam Generators §5.14 (losses) and §5.15 (credits)
- Channiwala & Parikh (2002) for GCV when not entered
Questions and answers
Why are losses and credits referred to 25 °C instead of the air temperature?
PTC 4 fixes the reference at 25 °C (77 °F) so that results are comparable between tests. Air entering above 25 °C brings heat in, which appears as a credit; the two together give the same answer as referencing to the air temperature when the air is at ambient.
What is the difference between the gross and net efficiency?
The gross (HHV) basis counts the latent heat of the water in the flue gas as a loss; the net (LHV) basis leaves it out of both input and loss. The net figure is 4–6 points higher for coal and 9–11 points higher for natural gas. State the basis whenever you quote an efficiency.
Where do I get the unburned carbon?
From the ash analysis: carbon in bottom ash and fly ash times the ash flows, divided by the fuel flow. 0.3–1 % of fuel is typical for stokers and fluidised beds, below 0.1 % for pulverised coal and nil for oil.
How does this differ from BS 845 / IS 8753?
The loss list is the same in substance. BS 845 references losses to the ambient air temperature and has no separate credits; PTC 4 references to 25 °C and adds credits. For air at 25 °C the two give identical results.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.