Load on Boiler Stays, Flat Plates and Manhole Doors

Load carried by each stay of a stayed flat plate from the pressure and the stay pitches, the stress in the stay, and the total load on an elliptical manhole door.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 10 kg/cm² g, 200 x 200 mm pitch, 30 mm stays, 400 x 300 manhole14 bar g, 180 x 220 mm, 32 mm, 70 MPa, 410 x 3107 kg/cm² g, 150 mm square, 25 mm, no manhole

Stays

Manhole door

Results

Each stay carries the pressure on one pitch × pitch rectangle of plate (the stay's own area is not deducted). Plate thickness between stays is a code calculation and is not done here.

Plate area carried by one stay0.040000m²
Load on one stay39.227kN
Stress in the stay55.494MPa
Smallest stay diameter for the allowable stress25.806mm
Manhole area0.094248m²
Total load on the manhole door92.425kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 kg/cm² g, 200 x 200 mm pitch, 30 mm stays, 400 x 300 manhole. The inputs, in the units selected above:

InputValue
Working pressure9.8066 bar g
Horizontal pitch of the stays200.00 mm
Vertical pitch of the stays200.00 mm
Stay diameter (at the root of the thread)30.000 mm
Allowable stress in the stay75.000 MPa
Manhole major axis400.00 mm
Manhole minor axis300.00 mm

Applying the formula below gives:

ResultValue
Plate area carried by one stay0.040000 m²
Load on one stay39.227 kN
Stress in the stay55.494 MPa
Smallest stay diameter for the allowable stress25.806 mm
Manhole area0.094248 m²
Total load on the manhole door92.425 kN

Open this example in the calculator and change any input.

Formula

\(F_s = (p - p_{atm})\, p_h\, p_v, \quad \sigma = \frac{F_s}{\pi d^2 / 4}, \quad d_{min} = \sqrt{\frac{4 F_s}{\pi \sigma_a}}\)

\(F_m = (p - p_{atm})\, \frac{\pi a b}{4}\)

Variables

Symbol Meaning SI unit
\(p\) Working pressure Pa
\(p_h\) Horizontal pitch of the stays m
\(p_v\) Vertical pitch of the stays m
\(d\) Stay diameter (at the root of the thread) m
\(\sigma_a\) Allowable stress in the stay Pa
\(a\) Manhole major axis m
\(b\) Manhole minor axis m
\(A_s\) Plate area carried by one stay m²
\(F_s\) Load on one stay N
\(\sigma\) Stress in the stay Pa
\(d_{min}\) Smallest stay diameter for the allowable stress m
\(A_m\) Manhole area m²
\(F_m\) Total load on the manhole door N

Method and standards

Each stay supports the rectangle of plate around it; the manhole door carries the pressure on its whole elliptical area.

Worked example

Stays are pitched 200 mm × 200 mm on a flat plate at 10 kg/cm² g; the stays are 30 mm at the thread root.

  • Area per stay = 20 cm × 20 cm = 400 cm²
  • Load = 10 kg/cm² × 400 cm² = 4000 kgf = 39.2 kN
  • Stress = 39 227 N / (π × 30²/4 mm²) = 55.5 N/mm²

Where it is used

  • Boiler attendant and operator examinations.
  • Understanding why flat surfaces of boilers need stays.
  • Manhole and mudhole door handling.

Common mistakes

  • Using absolute pressure.
  • Using the outside thread diameter instead of the root.
  • Forgetting that pressure acts on the whole door area.

Assumptions and limits

  • Stay area not deducted from the supported area.
  • The manhole load is the pressure on the a × b ellipse you enter: for an internal door the pressure acts out to the gasket line, so enter the axes at the gasket (not the clear opening) for the load the door and its studs carry.
  • No code check of plate or stay; a warning is given only when the stay stress exceeds the allowable stress entered.

References

  • Pressure × supported area (statics, textbook)

Questions and answers

What load does a stay carry at 10 kg/cm² g with 200 mm × 200 mm pitch?

39.2 kN (4000 kgf). In a 30 mm stay that is 55.5 MPa; for 75 MPa allowable the stay needs at least 25.8 mm at the root.

What load is on a 400 × 300 mm manhole door?

The area is 0.0942 m², so 92.4 kN (9.4 tonnes-force) at 10 kg/cm² g: why the door sits inside, pressed onto its seat.

Is plate thickness checked?

No; flat-plate thickness between stays follows the code's formulas.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.