Worked example
Example: Shell boiler 10 t/h, 10.5 bar(a) saturated, feed 105 °C, coal 1.65 t/h at 18.6 MJ/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 10,000 kg/h |
| Steam pressure (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Feedwater temperature | 105.00 °C |
| Fuel flow | 1,650.0 kg/h |
| Gross calorific value of the fuel, as fired | 18,600 kJ/kg |
| Blowdown, as a share of steam | 0 % |
| Drum pressure (absolute), for blowdown and feedwater; 0 = steam pressure | 0 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Boiler efficiency (on GCV) | 76.183 % |
| Heat to steam and blowdown | 6,494.6 kW |
| Heat input from fuel | 8,525.0 kW |
| Evaporation ratio | 6.0606 kg/kg |
| Steam enthalpy | 2,779.0 kJ/kg |
| Feedwater enthalpy | 440.90 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\eta = \frac{\dot Q_{out}}{\dot Q_{in}} = \frac{\dot m_s\,(h_s - h_{fw}) + b\,\dot m_s\,(h_f - h_{fw})}{\dot m_f \cdot GCV}\)
\(\text{evaporation ratio} = \dot m_s/\dot m_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam flow | kg/s |
| \(p\) | steam pressure, absolute | Pa |
| \(\text{state}\) | saturated or superheated steam | – |
| \(T_s\) | steam temperature (superheated steam) | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(\dot m_f\) | fuel flow | kg/s |
| \(GCV\) | gross calorific value of the fuel, as fired | J/kg |
| \(b\) | blowdown as a share of steam flow | – |
| \(\eta\) | boiler efficiency on GCV | – |
| \(\dot Q_{out}\) | heat given to steam and blowdown | W |
| \(\dot Q_{in}\) | heat input from fuel | W |
| \(\dot m_s/\dot m_f\) | evaporation ratio, kg steam per kg fuel | kg/kg |
| \(h_s\) | steam enthalpy | J/kg |
| \(h_{fw}\) | feedwater enthalpy at the drum pressure \(p_d\) | J/kg |
| \(h_f\) | saturated water enthalpy (blowdown) at the drum pressure \(p_d\) | J/kg |
| \(p_d\) | drum pressure, absolute; 0 takes the steam pressure \(p\) | Pa |
Method and standards
Input–output (direct) efficiency as defined in ASME PTC 4 and in the Indian practice of IS 8753: useful heat to the working fluid divided by the chemical energy of the fuel on the gross (higher) calorific value. Steam, feedwater and blowdown enthalpies from FireCAD's IAPWS-IF97.
Where it is used
- Daily and monthly efficiency reports of process and captive boilers from the steam and fuel meters.
- Energy audits (Bureau of Energy Efficiency, India), as the first quick check before a full loss analysis.
- Comparing fuels, operators or shifts by their steam-to-fuel ratio.
- Checking a vendor's guarantee when a full PTC 4 test is not justified.
Common mistakes
- Using a steam meter set for another pressure: an orifice meter misreads when the density changes.
- Taking GCV on the air-dried basis while weighing the fuel as fired (or the reverse): the moisture difference shifts efficiency by several points.
- Mixing GCV and NCV: NCV-based efficiency is 4–8 points higher for coal and about 10 points for natural gas.
- Forgetting blowdown and soot-blowing steam when the meter is downstream of them.
- Testing over too short a period: fuel in the hopper and furnace makes short tests unreliable; test for several hours at steady load.
Assumptions and limits
- Steady load; the fuel and steam quantities cover the same period.
- Gross calorific value of the fuel as fired; sensible heat in fuel and air, and auxiliary power, are not counted.
- No heat credits; steam leaving dry (saturated) or at the given temperature (superheated). Wet steam cannot be entered; carry-over moisture would make the efficiency read high.
- Feedwater and blowdown enthalpies are taken at the drum pressure; left at 0 it is the steam pressure. In a superheater boiler the drum runs above the outlet pressure by the superheater pressure drop: enter it for the blowdown heat to be exact.
- The 95 % warning is a FireCAD plausibility limit for non-condensing boilers.
References
- ASME PTC 4-2013 Fired Steam Generators (input–output method)
- BIS IS 8753 (boiler efficiency, Indian practice)
- IAPWS R7-97(2012) IF97
Questions and answers
How is boiler efficiency calculated by the direct method?
Divide the heat given to the steam by the heat in the fuel fired. A 10 t/h boiler making saturated steam at 10.5 bar(a) from feedwater at 105 °C adds 2338 kJ per kg; burning 1.65 t/h of coal at 18.6 MJ/kg it is 76.2 % efficient, with an evaporation ratio of 6.06.
Direct or indirect method?
The direct method needs only two meters and a fuel sample, but a 2 % error in the steam or fuel meter is a 2 % error in efficiency, and it says nothing about where the heat goes. The indirect (loss) method is more accurate and shows what to fix; use both and compare.
Should blowdown be counted?
Yes, if the steam meter reads the steam only. Blowdown leaves the drum as saturated water heated from the feedwater temperature; enter it as a share of the steam flow.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.