Worked example
Example: Coal boiler 80 MW input. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat input from fuel (on GCV) | 80.000 MW |
| Dry flue gas loss | 5.5000 % |
| Loss from water formed from hydrogen | 4.0000 % |
| Loss from moisture in the fuel | 3.5000 % |
| Loss from moisture in the air | 0.20000 % |
| Loss from CO (incomplete combustion) | 0.20000 % |
| Loss from unburned carbon in ash | 1.2000 % |
| Sensible heat in ash | 0.30000 % |
| Surface radiation and convection loss | 1.0000 % |
| Unaccounted and manufacturer's margin | 1.0000 % |
| Heat credits (entering air and fuel above the reference, steam air heater, mill power) | 0.50000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Boiler efficiency (on GCV) | 83.600 % |
| Total losses | 16.900 % |
| Heat to steam | 66.880 MW |
| Total heat lost | 13.520 MW |
| Heat lost in dry flue gas | 4.4000 MW |
| Heat lost in water vapour (hydrogen, fuel and air moisture) | 6.1600 MW |
Open this example in the calculator and change any input.
Formula
\(\Sigma L = L_{dg} + L_{H} + L_{m} + L_{am} + L_{CO} + L_{C} + L_{ash} + L_{r} + L_{u} \qquad \eta = 1 - \Sigma L + B\)
\(\dot Q_{out} = \eta\,\dot Q_{in} \qquad \dot Q_L = \Sigma L\,\dot Q_{in} \qquad \dot Q_{dg} = L_{dg}\,\dot Q_{in} \qquad \dot Q_{w} = (L_H + L_m + L_{am})\,\dot Q_{in}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q_{in}\) | heat input from fuel, on GCV | W |
| \(L_{dg}\) | dry flue gas loss | – |
| \(L_{H}\) | loss from water formed from hydrogen | – |
| \(L_{m}\) | loss from moisture in the fuel | – |
| \(L_{am}\) | loss from moisture in the air | – |
| \(L_{CO}\) | loss from CO | – |
| \(L_{C}\) | unburned carbon loss | – |
| \(L_{ash}\) | sensible heat in ash | – |
| \(L_{r}\) | surface radiation and convection loss | – |
| \(L_{u}\) | unaccounted loss and margin | – |
| \(B\) | heat credits as a share of input | – |
| \(\eta\) | boiler efficiency on GCV | – |
| \(\Sigma L\) | total losses | – |
| \(\dot Q_{out}\) | heat to steam | W |
| \(\dot Q_L\) | total heat lost | W |
| \(\dot Q_{dg}\) | heat lost in dry flue gas | W |
| \(\dot Q_{w}\) | heat lost in water vapour | W |
Method and standards
Efficiency by the energy-balance (heat-loss) method of ASME PTC 4 §5: efficiency is 100 % less losses plus credits, all as fractions of the fuel input on the gross calorific value. Indian practice (IS 8753, BEE audit guides) uses the same list of losses.
Where it is used
- Presenting an efficiency test or energy audit as a heat balance sheet or Sankey diagram.
- Checking a boiler maker's guaranteed efficiency breakdown at the proposal stage.
- Ranking improvement projects by the size of each loss in MW.
- Training operators on where the fuel's heat goes.
Common mistakes
- Mixing losses computed on NCV with others on GCV.
- Counting the manufacturer's margin twice: it is often already inside the unaccounted line.
- Entering a credit as a negative loss and again as a credit.
- Taking the surface loss of a large boiler as a fixed 2 %: it is a fraction of 1 % at full load and rises at part load.
Assumptions and limits
- Each loss is entered as a fraction of the heat input on GCV; this page does not compute the losses themselves.
- Credits are entered as one combined fraction: entering air and fuel above the reference temperature, a steam air heater, mill power.
- All losses and credits must be referred to the same reference temperature (25 °C in ASME PTC 4; the ambient air temperature in BS 845 and IS 8753, which then has no air credit).
- A warning appears above 95 % efficiency on GCV.
References
- ASME PTC 4-2013 Fired Steam Generators §5.14 (losses) and §5.15 (credits)
- BIS IS 8753 (boiler efficiency)
Questions and answers
What is a boiler energy balance?
A sheet that splits the heat in the fuel into heat to steam and each loss. For an 80 MW coal boiler with losses of 16.9 % and credits of 0.5 %, the efficiency is 83.6 %; 66.9 MW reaches the steam and 13.5 MW is lost, 4.4 MW of it in dry flue gas.
Where do the individual losses come from?
From the indirect-method calculation (boiler efficiency, ASME PTC 4) or the separate loss calculators here for unburned carbon, CO, ash sensible heat and surface loss. This page adds them up and turns them into MW.
Which losses are usually the largest?
Dry flue gas and water vapour from hydrogen and moisture, together 10–15 % for coal. Unburned carbon matters for high-ash coal and fluidised beds; surface loss is under 1 % for large boilers but 1–3 % for small shell boilers.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.