Worked example
Example: 120 tubes 57 mm x 4.5 m, 900 mm furnace, 3 m² other, 5 t/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of smoke tubes | 120.00 - |
| Tube inside diameter (fire side) | 57.000 mm |
| Tube length | 4.5000 m |
| Furnace inside diameter | 900.00 mm |
| Furnace length | 4.5000 m |
| Other heated surface (reversal chamber, tube plates) | 3.0000 m² |
| Steam output | 5,000.0 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tube heating surface n π d_t L_t | 96.698 m² |
| Furnace heating surface π D_f L_f | 12.723 m² |
| Total heating surface | 112.42 m² |
| Evaporation per m² of heating surface | 0.012354 kg/(m²·s) |
Open this example in the calculator and change any input.
Formula
\(A = n\, \pi\, d_t\, L_t + \pi\, D_f\, L_f + A_x\)
\(e = \frac{\dot m_s}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of smoke tubes | - |
| \(d_t\) | Tube inside diameter (fire side) | m |
| \(L_t\) | Tube length | m |
| \(D_f\) | Furnace inside diameter | m |
| \(L_f\) | Furnace length | m |
| \(A_x\) | Other heated surface (reversal chamber, tube plates) | m² |
| \(\dot m_s\) | Steam output | kg/s |
| \(A_t\) | Tube heating surface n π d_t L_t | m² |
| \(A_f\) | Furnace heating surface π D_f L_f | m² |
| \(A\) | Total heating surface | m² |
| \(e\) | Evaporation per m² of heating surface | kg/(m²·s) |
Method and standards
Geometric area of the heated surfaces on the gas side.
Worked example
A boiler has 120 smoke tubes of 57 mm bore and 4.5 m length, a 900 mm furnace 4.5 m long and 3 m² of other heated surface; it makes 5 t/h.
- Tubes: 120 × π × 0.057 × 4.5 = 96.7 m²
- Furnace: π × 0.9 × 4.5 = 12.7 m²
- Total = 112.4 m²; evaporation = 5000 / 112.4 = 44.5 kg/(m²·h)
Where it is used
- Boiler attendant examinations.
- Comparing boilers and checking a nameplate rating.
- Registration papers list the heating surface.
Common mistakes
- Using outside diameter of smoke tubes (the gas is inside).
- Counting the water side.
- Mixing mm and m.
Assumptions and limits
- Plain tubes; corrugated furnaces counted by their mean diameter.
- Other surfaces entered by the user.
- Heating surface measured on the side touched by the hot gas: inside the smoke tubes and inside the furnace.
References
- Fire-side area of tubes and furnace (geometry)
Questions and answers
What heating surface do 120 tubes of 57 mm bore, 4.5 m long, and a 900 mm furnace give?
Tubes 96.7 m², furnace 12.7 m², with 3 m² of other surfaces 112.4 m². At 5 t/h that is 44.5 kg of steam per m² per hour.
Which diameter is used?
The side touched by the hot gases: inside the smoke tubes and inside the furnace tube.
Why does heating surface matter?
It sets how much heat the boiler can take in, and in India the boiler attendant's certificate class depends on the heating surface of the boilers in charge. For that purpose the regulation's own definition of heating surface governs (which side and which parts count); this calculator gives the gas-side geometric area.