Worked example
Example: Ganapathy: gas, 15 %, 280/80 °F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel | Natural gas |
| Excess air | 15.000 % |
| Exit gas temperature | 137.78 °C |
| Ambient temperature | 26.667 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Efficiency, HHV basis | 84.690 % |
| Efficiency, LHV basis | 93.783 % |
Open this example in the calculator and change any input.
Formula
Natural gas:
\(\eta_{HHV} = 89.4 - (0.001123 + 0.0195\,f)\,\Delta T, \quad \eta_{LHV} = 99.0 - (0.001244 + 0.0216\,f)\,\Delta T\)
Fuel oil:
\(\eta_{HHV} = 92.9 - (0.001298 + 0.01905\,f)\,\Delta T, \quad \eta_{LHV} = 99.0 - (0.001383 + 0.0203\,f)\,\Delta T\)
\(f = 1 + EA, \quad \Delta T = 1.8\,(t_g - t_a) \text{ in °F}, \quad \eta \text{ in per cent}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{fuel}\) | Fuel | - |
| \(EA\) | Excess air, fraction (15 % = 0.15) | - |
| \(f\) | excess air factor, \(1 + EA\) | - |
| \(\Delta T\) | exit gas minus ambient temperature, in °F | °F |
| \(t_g\) | Exit gas temperature | K |
| \(t_a\) | Ambient temperature | K |
| \(\eta_{HHV}\) | Efficiency, HHV basis | - |
| \(\eta_{LHV}\) | Efficiency, LHV basis | - |
Method and standards
Ganapathy's Eqs. (16a–b), derived from combustion calculations for typical gas and oil; the HHV and LHV forms are both from the same source.
Where it is used
- Operator checks of package boilers.
- Excess air tuning.
Common mistakes
- Using for coal or biomass.
- Entering ΔT in kelvin into the °F formula (the calculator converts).
Assumptions and limits
- Natural gas or fuel oil; 1 % other losses.
- A warning appears above 60 % excess air or 300 K gas-to-ambient difference, where the linear fit is extrapolated.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q2.22
- Eqs. (16a) and (16b)
Questions and answers
How good is it?
Within about half a point for typical natural gas and oil firing.
What is EA here?
You enter the excess air (15 %); the formula uses the excess air factor f = 1 + EA, so 15 % excess air is 1.15.
What does Ganapathy's example give?
Natural gas, 15 % excess air, 280 °F stack and 80 °F ambient: 84.6 % HHV, 93.8 % LHV.