Worked example
Example: 10 t/h at 10.5 bar(a) saturated, feed 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam output | 10,000 kg/h |
| Steam pressure (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Feedwater temperature | 105.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat output | 6,494.6 kW |
| Equivalent evaporation from and at 100 °C | 10,362 kg/h |
| Boiler horsepower | 662.12 |
| Factor of evaporation | 1.0362 |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_s\,(h_s - h_{fw}) \qquad F = \frac{h_s - h_{fw}}{h_{fg,100}} \qquad \dot m_e = \frac{\dot Q}{h_{fg,100}}\)
\(BHP = \frac{\dot m_e}{34.5\ \text{lb/h}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam output | kg/s |
| \(p\) | steam pressure, absolute | Pa |
| \(\text{state}\) | saturated or superheated steam | – |
| \(T_s\) | steam temperature (superheated) | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(\dot Q\) | heat output | W |
| \(\dot m_e\) | equivalent evaporation from and at 100 °C | kg/s |
| \(BHP\) | boiler horsepower | – |
| \(F\) | factor of evaporation | – |
| \(h_s\) | steam enthalpy | J/kg |
| \(h_{fw}\) | feedwater enthalpy | J/kg |
| \(h_{fg,100}\) | latent heat at 100 °C, computed from IF97 (about 2256.5 kJ/kg) | J/kg |
Method and standards
Heat output from IAPWS-IF97 enthalpies; equivalent evaporation from and at 100 °C with the IF97 latent heat at 100 °C; boiler horsepower as 34.5 lb/h of water evaporated from and at 212 °F (the ASME and ABMA definition).
Where it is used
- Comparing quotations rated in t/h, kW, kcal/h, BHP or F&A.
- Converting an imported (US) boiler rating to SI.
- Checking boiler capacity against a heat load.
Common mistakes
- Treating an F&A rating as the actual steam output: at 10 bar and 80 °C feed the real output is about 5–10 % less.
- Confusing boiler horsepower with mechanical horsepower (745.7 W).
- Using gauge pressure as absolute.
Assumptions and limits
- Steam dry saturated or at the given superheat; no blowdown.
References
- ASME definition of boiler horsepower (34.5 lb/h from and at 212 °F)
- IAPWS R7-97(2012) IF97
Questions and answers
How do I convert boiler t/h to kW?
Multiply the steam flow by the heat added per kg. 10 t/h of saturated steam at 10.5 bar(a) from feedwater at 105 °C is 6.49 MW, equivalent to 10.36 t/h from and at 100 °C, or 662 boiler horsepower.
What is "from and at 100 °C"?
The steam a boiler would make if it received water at 100 °C and made saturated steam at 100 °C, so every kg takes 2257 kJ. It lets boilers working at different pressures and feed temperatures be compared; shell boiler makers often quote it.
What is a boiler horsepower?
An American unit: 34.5 lb/h of water evaporated from and at 212 °F, about 9.81 kW. It has nothing to do with mechanical horsepower.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.