Worked example
Example: 12 MW minimum firing. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel heat input at minimum stable firing | 12.000 MW |
| Boiler efficiency at that firing | 70.000 % |
| Steam pressure at the vent (absolute) | 20.000 bar |
| Steam temperature | 300.00 °C |
| Feedwater temperature | 80.000 °C |
| Drum (feedwater) pressure (absolute) | 20.000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam to vent or bypass | 11.251 t/h |
| Heat in the vented steam | 8.4000 MW |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{\eta\,\dot Q_{min}}{h_s - h_{fw}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q_{min}\) | Fuel heat input at minimum stable firing | W |
| \(\eta\) | Boiler efficiency at that firing | - |
| \(p\) | Steam pressure at the vent (absolute) | Pa |
| \(T_s\) | Steam temperature | K |
| \(T_{fw}\) | Feedwater temperature | K |
| \(p_{fw}\) | Drum (feedwater) pressure (absolute) | Pa |
| \(h_s\), \(h_{fw}\) | steam enthalpy at the vent (p, T_s) and feedwater enthalpy at (p_fw, T_fw), IF97 | J/kg |
| \(\dot m_s\) | Steam to vent or bypass | kg/s |
| \(\dot Q_l\) | Heat in the vented steam | W |
Method and standards
Energy balance: the heat absorbed at minimum firing (input times efficiency) all goes into raising steam from the feedwater to the vented state, with IAPWS-IF97 enthalpies (steam at the vent conditions, feedwater at the drum pressure).
Where it is used
- Start-up vent and silencer sizing.
- Start-up cost estimates.
Common mistakes
- Full-load efficiency at minimum firing.
Assumptions and limits
- Steady minimum firing.
- Feedwater must be liquid at the drum pressure.
- All the absorbed heat is taken to make vented steam. During a real start-up part of it heats the water and metal, so the vent flow found is an upper bound, suitable for sizing the vent and silencer.
References
- Energy balance with IAPWS-IF97 enthalpies
Questions and answers
Why vent steam at start-up?
Superheater tubes need steam flow to stay cool before the turbine or process can take it.
Cost?
The vented heat is lost; shorter start-ups and bypass to a condenser recover some.
Minimum stable firing?
Set by burners or grate and by circulation: take it from the maker.