Worked example
Example: Indian coal, bottom ash 600 °C, fly ash 140 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ash in the fuel, as fired | 35.000 % |
| Share of ash leaving as fly ash | 80.000 % |
| Carbon in the residue | 2.0000 % |
| Bottom ash temperature leaving the furnace | 600.00 °C |
| Fly ash temperature (gas temperature leaving the boiler) | 140.00 °C |
| Reference temperature | 25.000 °C |
| Mean specific heat of the residue | 0.83736 kJ/(kg·K) |
| Gross calorific value of the fuel, as fired | 18,600 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Sensible heat loss in ash, % of heat input | 0.33282 % |
| Of which in bottom ash | 0.18490 % |
| Of which in fly ash | 0.14792 % |
| Residue per kg of fuel | 0.35714 kg/kg |
Open this example in the calculator and change any input.
Formula
\(m_r = \frac{A}{1 - c_r}\)
\(L_b = \frac{m_r\,(1 - x_f)\,c_{p,r}\,(T_b - T_{ref})}{GCV} \qquad L_f = \frac{m_r\,x_f\,c_{p,r}\,(T_f - T_{ref})}{GCV} \qquad L_{ash} = L_b + L_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | ash in fuel, as fired | – |
| \(x_f\) | share of ash leaving as fly ash | – |
| \(c_r\) | carbon in residue | – |
| \(T_b\) | bottom ash temperature leaving | K |
| \(T_f\) | fly ash temperature (flue gas leaving) | K |
| \(T_{ref}\) | reference temperature, 25 °C in PTC 4 | K |
| \(c_{p,r}\) | mean specific heat of residue | J/(kg·K) |
| \(GCV\) | gross calorific value | J/kg |
| \(L_{ash}\) | sensible heat loss in ash | – |
| \(L_b\) | of which in bottom ash | – |
| \(L_f\) | of which in fly ash | – |
| \(m_r\) | residue per kg of fuel | kg/kg |
Method and standards
Sensible heat of residue as in ASME PTC 4: residue mass times mean specific heat times its rise above the reference temperature, split into bottom ash and fly ash. The default specific heat is 0.2 Btu/(lb·°F) = 837 J/(kg·K) for coal and biomass ash (FireCAD practice, confirmed 2026-11-11).
Where it is used
- Complete loss accounting in efficiency tests of high-ash coal, lignite and biomass boilers.
- Comparing dry and wet bottom-ash handling.
- Fluidised-bed boilers that drain hot bed material.
Common mistakes
- Using the furnace temperature for bottom ash that cools on a grate or in a hopper before it leaves.
- Applying the bottom-ash temperature to all the ash.
- Ignoring bed drain and economiser or air heater hopper ash in fluidised beds.
Assumptions and limits
- One mean specific heat for both ash streams; ash temperatures below the reference are rejected.
- Fly ash leaves at the flue gas temperature.
References
- ASME PTC 4-2013 Fired Steam Generators (sensible heat of residue)
- BIS IS 8753 (boiler efficiency)
Questions and answers
How big is the ash sensible heat loss?
Usually small. Coal with 35 % ash, 20 % of it leaving as bottom ash at 600 °C and the rest as fly ash at 140 °C, loses 0.33 % of the heat input. It matters most for high-ash coal with dry bottom-ash removal and for hot bed drain from fluidised beds.
What specific heat should I use?
FireCAD uses 0.2 Btu/(lb·°F) = 0.837 kJ/(kg·K) for both coal and biomass ash. ASME PTC 4 gives a temperature-dependent curve; enter your own value if you have a measured or code figure.
What temperature for bottom ash?
The temperature at which it leaves the boiler boundary: several hundred °C from a dry hopper or grate, much lower if it is quenched in a water seal inside the boundary.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.