Pressure Decay after a Firing Trip (Stored Energy)

Time for drum pressure to fall between two values after firing stops while steam is drawn, from water and steel stored energy (IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 46 to 36 bar, 30 t/h drawnSmall boiler

Results

Flash steam is taken at the lower pressure's latent heat (conservative); heat still stored in refractory and the setting adds a little time.

Stored energy released3,943.3MJ
Steam made from stored energy2.2599t
Time to fall to p₂4.5198min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 46 to 36 bar, 30 t/h drawn. The inputs, in the units selected above:

InputValue
Water in drum, risers and downcomers40.000 t
Steel in contact with the water150.00 t
Steel specific heat0.50000 kJ/(kg·K)
Pressure at the trip (absolute)46.000 bar
Pressure reached (absolute)36.000 bar
Steam still drawn30.000 t/h

Applying the formula below gives:

ResultValue
Stored energy released3,943.3 MJ
Steam made from stored energy2.2599 t
Time to fall to p₂4.5198 min

Open this example in the calculator and change any input.

Formula

\(E = M_w[h_f(p_1) - h_f(p_2)] + M_m c_m [T_s(p_1) - T_s(p_2)], \quad t = \frac{E}{h_{fg}(p_2)\,\dot m_s}\)

Variables

Symbol Meaning SI unit
\(M_w\) Water in drum, risers and downcomers kg
\(M_m\) Steel in contact with the water kg
\(c_m\) Steel specific heat J/(kg·K)
\(p_1\) Pressure at the trip (absolute) Pa
\(p_2\) Pressure reached (absolute) Pa
\(\dot m_s\) Steam still drawn kg/s
\(E\) Stored energy released J
\(M_s\) Steam made from stored energy kg
\(t\) Time to fall to p₂ s

Method and standards

A lumped energy balance between two saturation states with IAPWS-IF97: the heat given up by the saturated water and the steel as the saturation temperature falls from \(T_s(p_1)\) to \(T_s(p_2)\) makes steam at the latent heat of the lower pressure \(p_2\). The time follows from a constant steam draw. Holding the water mass constant and using \(h_{fg}(p_2)\), the largest latent heat in the range, gives slightly less steam and so a slightly shorter, conservative time than a step-by-step balance in which the water inventory falls as it flashes.

Where it is used

  • Ride-through studies.
  • Operator training.

Common mistakes

  • Ignoring steel mass.

Assumptions and limits

  • Saturated, well-mixed water; constant steam draw; no firing and no feedwater during the decay.
  • Water mass held constant; a warning appears when the steam made exceeds 20 % of the water, when drum level may trip the boiler first.

References

  • Energy balance of saturated water and steel between two saturation states (IAPWS-IF97)

Questions and answers

Why does a boiler keep steaming after a trip?

Hot water flashes as pressure falls, and the steel gives up heat.

Use?

Judging how long a turbine or process can ride through a fuel interruption.

Bagasse feeding hiccups?

Short interruptions are absorbed by this stored energy; long ones are not.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.