Worked example
Example: Indian coal, O2 6 % to 4 %, gas 160 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| O₂ in dry flue gas now | 6.0000 % |
| O₂ in dry flue gas after tuning | 4.0000 % |
| Carbon | 45.000 % |
| Hydrogen | 3.5000 % |
| Oxygen | 5.0000 % |
| Nitrogen | 1.0000 % |
| Sulphur | 0.50000 % |
| Ash | 35.000 % |
| Moisture | 10.000 % |
| Air humidity (kg water per kg dry air) | 0.013000 kg/kg |
| Gross calorific value of the fuel, as fired | 18,600 kJ/kg |
| Flue gas temperature at the boiler exit | 160.00 °C |
| Combustion air temperature | 30.000 °C |
| Boiler efficiency now (on GCV) | 76.000 % |
| Fuel firing rate | 12,000 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel saved, share of present fuel | 0.93392 % |
| Fuel saved | 112.07 kg/h |
| Efficiency after | 76.716 % |
| Excess air now | 38.863 % |
| Excess air after | 22.852 % |
| Sensible flue gas loss now | 6.8861 % |
| Sensible flue gas loss after | 6.1696 % |
Open this example in the calculator and change any input.
Formula
\(n_{a,0} = \frac{1}{0.2095}\left(\frac{C}{12.011} + \frac{H}{4.032} + \frac{S}{32.06} - \frac{O}{31.998}\right), \quad n_{dg,0} = \frac{C}{12.011} + \frac{S}{32.06} + \frac{N}{28.014} + 0.7905\,n_{a,0}\)
\(EA = \frac{O_2\,n_{dg,0}}{n_{a,0}\,(0.2095 - O_2)} \qquad L = \frac{m_g(EA)\,\left[h_g(T_g) - h_g(T_a)\right]}{GCV}\)
\(\eta_2 = \eta_1 + L_1 - L_2 \qquad s = 1 - \frac{\eta_1}{\eta_2} \qquad \Delta\dot m_f = s\,\dot m_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(O_{2,1}\) | O₂ in dry flue gas now | – |
| \(O_{2,2}\) | O₂ in dry flue gas after tuning | – |
| \(C\), \(H\), \(O\), \(N\), \(S\), \(A\), \(M\) | ultimate analysis as fired, mass fractions | – |
| \(\omega\) | air humidity, kg water per kg dry air | kg/kg |
| \(GCV\) | gross calorific value | J/kg |
| \(T_g\) | flue gas temperature at the boiler exit | K |
| \(T_a\) | combustion air temperature | K |
| \(\eta_1\) | boiler efficiency now, on GCV | – |
| \(\dot m_f\) | fuel firing rate now | kg/s |
| \(s\) | fuel saved, share of present fuel | – |
| \(\Delta\dot m_f\) | fuel saved | kg/s |
| \(\eta_2\) | efficiency after | – |
| \(EA_1\) | excess air now | – |
| \(EA_2\) | excess air after | – |
| \(L_1\) | stack loss now | – |
| \(L_2\) | stack loss after | – |
| \(EA\), \(O_2\) | excess air and dry O₂ in general | – |
| \(n_{a,0}\) | theoretical dry air per kg fuel | kmol/kg |
| \(n_{dg,0}\) | dry flue gas per kg fuel at zero excess air | kmol/kg |
| \(m_g\) | wet flue gas per kg fuel | kg/kg |
| \(h_g\) | enthalpy of the wet flue gas | J/kg |
Method and standards
Excess air from the dry O₂ by an exact oxygen balance of the fuel analysis. Stack loss (dry gas plus water vapour sensible heat between the air and gas temperatures) from FireCAD's combustion balance and NIST Shomate enthalpies, as in the ASME PTC 4 losses. The CO loss is not included: keep O₂ above the point where CO rises.
Where it is used
- Combustion tuning and O₂ trim projects on boilers, furnaces and thermic fluid heaters.
- Energy audits: valuing an O₂ analyser or a trim system.
- Explaining to operators why "more air for safety" costs fuel.
Common mistakes
- Reading O₂ after an air heater or a leaking duct, which shows more excess air than the furnace has.
- Going below the CO floor: the CO loss and soot rise faster than the dry gas loss falls.
- Assuming the exit gas temperature stays the same; it usually falls slightly with less excess air, adding a little to the saving.
Assumptions and limits
- Exit gas and air temperatures unchanged; complete combustion at both O₂ levels.
- Water vapour leaves as vapour (no condensation).
- Dry-basis analyser and complete combustion: CO, unburned carbon and air in-leakage are not modelled. The fuel enters at the air temperature (no separate fuel sensible heat).
- If the O₂ after is higher than now, the result is an extra fuel use (negative saving), with a note.
- The flue gas losses shown are sensible heat only. The latent heat of the water from hydrogen and moisture does not change with excess air, so it cancels in the saving but is not part of the loss figures.
References
- ASME PTC 4-2013 §5.14 (dry gas and water vapour losses)
- NIST Chemistry WebBook Shomate equations
Questions and answers
How much fuel does lowering O₂ save?
For coal with gas leaving at 160 °C, cutting O₂ from 6 to 4 % (excess air 39 to 23 %) lowers the sensible stack loss from 6.89 to 6.17 % (the latent heat of the water is not counted; it does not change) and saves 0.93 % of the fuel. The saving grows with the gas temperature.
How low can O₂ go?
Until CO starts to rise. Gas burners often run at 1.5–3 % O₂, oil at 2–4 %, pulverised coal at 3–4 %, grate and biomass at 5–8 %. Find the floor with a combustion test and keep a margin.
Does lower excess air save fan power too?
Yes. Less air and less flue gas mean less FD and ID fan power, often a further 5–15 % of fan power on top of the fuel saving.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.