Worked example
Example: 1 t/h oil, 0.3 kg/kg, 8 bar(a), feed 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil firing rate | 1,000.0 kg/h |
| Atomising steam per kg of oil | 0.30000 kg/kg |
| Atomising steam pressure (absolute, saturated) | 8.0000 bar |
| Feedwater temperature (to value the steam) | 105.00 °C |
| Gross calorific value of the oil | 43,000 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Atomising steam | 300.00 kg/h |
| Heat in the atomising steam | 193.97 kW |
| Heat lost with it, share of fuel heat | 1.6239 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = r\,\dot m_o \qquad \dot Q = \dot m_s\,(h_g - h_{fw}) \qquad L = \frac{\dot Q}{\dot m_o \cdot GCV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_o\) | oil firing rate | kg/s |
| \(r\) | atomising steam per kg of oil | kg/kg |
| \(p_s\) | atomising steam pressure, absolute | Pa |
| \(T_{fw}\) | feedwater temperature | K |
| \(GCV\) | gross calorific value of the oil | J/kg |
| \(\dot m_s\) | atomising steam | kg/s |
| \(\dot Q\) | heat in the atomising steam | W |
| \(L\) | loss as a share of fuel heat | – |
| \(h_g\) | saturated steam enthalpy (IF97) | J/kg |
| \(h_{fw}\) | feedwater enthalpy (IF97) | J/kg |
Method and standards
Steam valued at the heat added from feedwater to saturated steam, with FireCAD's IAPWS-IF97; all of it is taken as lost with the flue gas. This is a simple upper estimate: strictly the stack carries the vapour at stack temperature and its low partial pressure, which differs from \(h_g\) by a few per cent. Feedwater enthalpy is taken at the atomising pressure, or just above its own saturation pressure when the feedwater is hotter than steam boils at that pressure.
Where it is used
- Boiler house steam and water balances.
- Comparing burner atomising methods.
- Checking burner settings against the maker's data.
Common mistakes
- Running atomising steam at a fixed high pressure at all loads.
- Using wet steam, which causes poor atomisation and flame instability.
- Forgetting the make-up water the steam consumes.
Assumptions and limits
- Saturated atomising steam; ratio from the burner maker.
References
- IAPWS R7-97(2012) IF97
- first law of thermodynamics
Questions and answers
How much steam does a steam-atomised burner use?
The oil flow times the maker's steam-to-oil ratio. 1 t/h of oil at 0.3 kg/kg uses 300 kg/h of steam; raised from 105 °C feedwater at 8 bar(a) it carries 194 kW, 1.6 % of the fuel heat, up the stack.
Can I reduce it?
Set the atomising steam pressure to the maker's curve, not higher; consider air atomising or pressure-jet burners where the oil and turndown allow.
Does it affect efficiency?
Yes, the steam leaves with the flue gas as vapour: the boiler loses its heat and the moisture loss rises.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.