Worked example
Example: 1 g coal, 2 kg water + 0.5 kg, 25.0 to 27.5 °C, 0.02 K cooling. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mass of fuel burnt | 1.0000 g |
| Mass of water in the calorimeter | 2.0000 kg |
| Water equivalent of the calorimeter | 0.50000 kg |
| Initial temperature | 25.000 °C |
| Final (highest) temperature | 27.500 °C |
| Cooling correction | 0.020000 K |
| Specific heat of water | 4.1868 kJ/(kg·K) |
| Fuse wire, thread and acid corrections | 0 J |
| Hydrogen in the fuel, same basis as the sample (for the net value) | 4.0000 % |
| Moisture in the sample burnt (for the net value) | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Corrected temperature rise | 2.5200 K |
| Heat released by the fuel | 26.377 kJ |
| Gross calorific value | 26,377 kJ/kg |
| Net calorific value | 25,504 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\Delta T = T_2 - T_1 + T_c\)
\(GCV = \frac{(m_w + m_e)\, c_w\, \Delta T - Q_c}{m_f}\)
\(NCV = GCV - \left(\frac{M_{H_2O}}{M_{H_2}} H + M\right) h_{fg,25}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_f\) | Mass of fuel burnt | kg |
| \(m_w\) | Mass of water in the calorimeter | kg |
| \(m_e\) | Water equivalent of the calorimeter | kg |
| \(T_1\) | Initial temperature | K |
| \(T_2\) | Final (highest) temperature | K |
| \(T_c\) | Cooling correction | K |
| \(c_w\) | Specific heat of water | J/(kg·K) |
| \(Q_c\) | Fuse wire, thread and acid corrections | J |
| \(H\) | Hydrogen in the fuel (for the net value) | - |
| \(M\) | Moisture in the fuel (for the net value) | - |
| \(\Delta T\) | Corrected temperature rise | K |
| \(Q\) | Heat released by the fuel | J |
| \(GCV\) | Gross calorific value | J/kg |
| \(NCV\) | Net calorific value | J/kg |
Method and standards
Heat released by the sample equals the heat taken up by the water and the calorimeter (water equivalent), less the heat from the fuse wire, thread and acid formation.
Worked example
1 g of coal is burnt in a bomb calorimeter holding 2 kg of water; water equivalent 0.5 kg. The temperature rises from 25.0 °C to 27.5 °C; cooling correction 0.02 K.
- Corrected rise = 2.5 + 0.02 = 2.52 K
- Heat = (2 + 0.5) × 4.1868 × 2.52 = 26.38 kJ
- GCV = 26.38 kJ / 0.001 kg = 26 377 kJ/kg = 6300 kcal/kg
- With 4 % hydrogen: NCV = 26 377 − 8.94 × 0.04 × 2442 = 25 504 kJ/kg
Where it is used
- Boiler attendant and operator examinations.
- Fuel laboratory checks of coal, oil and biomass.
- Understanding a coal test certificate.
Common mistakes
- Leaving out the water equivalent.
- Reading GCV as NCV.
- Forgetting the cooling correction on a long test.
Assumptions and limits
- Constant-volume gross value; the small difference from constant-pressure GCV is ignored.
- Corrections entered by the user.
- The net value is a simple latent-heat deduction from the constant-volume gross value. The net value at constant pressure defined in ISO 1928 and ASTM D5865 adds small terms for oxygen and nitrogen, so it differs slightly; use the standard's own procedure for a reported result.
- Hydrogen and moisture must be on the basis of the sample burnt (often air-dried); convert to as fired with the fuel basis conversion calculator.
References
- Bomb calorimeter heat balance (textbook; principle of ISO 1928 and ASTM D5865)
- Latent heat of water at 25 °C from IAPWS-IF97
Questions and answers
What GCV does a 1 g sample give with 2 kg water, 0.5 kg water equivalent and a 2.5 K rise?
With 0.02 K cooling correction the rise is 2.52 K: 2.5 kg × 4.1868 × 2.52 = 26.38 kJ, so GCV = 26.38 MJ/kg (6300 kcal/kg).
What is the water equivalent?
The mass of water with the same heat capacity as the bomb, bucket and stirrer; it is found by burning a standard such as benzoic acid.
How is the net value found?
The water formed from the hydrogen (8.94 kg per kg of H) and the moisture are taken as leaving as vapour: NCV = GCV − (8.94 H + M) × 2442 kJ/kg.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.