Worked example
Example: 45° vanes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vane angle (from the burner axis) | 45.000 ° |
| Hub diameter | 100.00 mm |
| Outer diameter | 300.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Swirl number | 0.72222 |
Open this example in the calculator and change any input.
Formula
\(S = \frac{2}{3}\,\frac{1 - (d_h/d)^3}{1 - (d_h/d)^2}\tan\theta\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\theta\) | Vane angle | rad |
| \(d_h\) | Hub diameter | m |
| \(d\) | Outer diameter | m |
| \(S\) | Swirl number | - |
Method and standards
Beér and Chigier, Combustion Aerodynamics: the flat-vane swirl number of an annular axial swirler, with about 0.6 as the threshold of strong swirl and central recirculation.
Where it is used
- Burner design and retrofits.
- Flame shape problems.
Common mistakes
- Angle measured from the radial direction.
Assumptions and limits
- Thin flat vanes; vane angle from the burner axis. Real vanes have thickness and the flow does not follow them exactly, so the actual swirl is lower than the flat-vane value; no correction is applied.
References
- Beér and Chigier
- Combustion Aerodynamics: S = (2/3)[1 − (d_h/d)³]/[1 − (d_h/d)²] tan θ for flat axial vanes
Questions and answers
Why swirl?
It creates a recirculation zone that brings hot gas back to ignite the incoming fuel.
Strong swirl threshold?
About 0.6, above which central recirculation appears.
Too much swirl?
Short wide flames that can impinge on walls and raise NOx.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.