Worked example
Example: Indian coal 12 t/h, 25 % excess air, 10 % leakage, 140 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon | 45.000 % |
| Hydrogen | 3.5000 % |
| Oxygen | 5.0000 % |
| Nitrogen | 1.0000 % |
| Sulphur | 0.50000 % |
| Ash | 35.000 % |
| Moisture | 10.000 % |
| Fuel firing rate at MCR | 12,000 kg/h |
| Excess air | 25.000 % |
| Air humidity (kg water per kg dry air) | 0.013000 kg/kg |
| Air in-leakage up to the fan, as a share of combustion air | 10.000 % |
| Gas temperature at the fan inlet | 140.00 °C |
| Flow margin | 20.000 % |
| Fans sharing the duty (1 = each fan 100 %) | 1.0000 - |
| Site pressure from | Altitude (ISO 2533 standard atmosphere) |
| Site altitude above sea level | 0 m |
| Barometric pressure at the site (absolute) | 1.0132 bar |
| Suction at the fan inlet (below barometric) | 203.94 mmWC |
| Fan pressure required at MCR (from the draught balance) | 254.93 mmWC |
| Pressure margin | 0 % |
| Fan efficiency | 80.000 % |
| Motor margin over the power absorbed | 10.000 % |
| Air temperature for the cold-start check | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Design volume flow per fan (at the fan inlet) | 157,337 m³/h |
| Design fan pressure | 254.93 mmWC |
| Standard motor rating (IEC 60072-1) | 160.00 kW |
| Minimum motor rating (absorbed + margin) | 150.23 kW |
| Power absorbed at the design point | 136.58 kW |
| Power with cold air at the same speed and flow | 183.83 kW |
| Design mass flow per fan | 133,431 kg/h |
| Gas density at the fan inlet | 0.84806 kg/m³ |
| Molar mass of the gas | 29.330 kg/kmol |
| Absolute pressure at the fan inlet | 0.99325 bar |
Open this example in the calculator and change any input.
Formula
Per kg of fuel, flue gas from the exact-ratio balance plus the leaking humid air:
\(\dot m_g = \dot m_f\left[m_g + l\,m_a(1+\omega)\right] \qquad \dot n_g = \dot m_f\left[n_g + l\left(\frac{m_a}{M_{da}} + \frac{m_a\,\omega}{M_w}\right)\right] \qquad M_g = \frac{\dot m_g}{\dot n_g}\)
\(p_{in} = p - \Delta p_{in} \qquad \rho_g = \frac{p_{in}\,M_g}{R\,T_g} \qquad \dot m = \dot m_g\,\frac{1 + m_Q}{n} \qquad \dot V = \frac{\dot m}{\rho_g}\)
\(\Delta p = \Delta p_{req}(1 + m_p) \qquad P_s = \frac{\dot V\,\Delta p}{\eta_f} \qquad P_{m,min} = P_s(1 + m_m) \qquad P_c = P_s\,\frac{\rho_{air}(T_c)}{\rho_g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\), \(H\), \(O\), \(N\), \(S\) | carbon, hydrogen, oxygen, nitrogen, sulphur in the fuel as fired | – |
| \(A\) | ash | – |
| \(M\) | moisture | – |
| \(\dot m_f\) | fuel firing rate at MCR | kg/s |
| \(EA\) | excess air | – |
| \(\omega\) | air humidity | kg/kg |
| \(l\) | air in-leakage as a share of combustion air | – |
| \(T_g\) | gas temperature at the fan inlet | K |
| \(m_Q\) | flow margin | – |
| \(n\) | fans sharing the duty | – |
| \(\text{site}\) | site pressure from altitude or entered | – |
| \(z\) | site altitude | m |
| \(p_s\) | barometric pressure entered | Pa |
| \(\Delta p_{in}\) | suction at the fan inlet | Pa |
| \(\Delta p_{req}\) | fan pressure required at MCR | Pa |
| \(m_p\) | pressure margin | – |
| \(\eta_f\) | fan efficiency | – |
| \(m_m\) | motor margin | – |
| \(T_c\) | air temperature at a cold start | K |
| \(\dot V\) | design volume flow per fan | m³/s |
| \(\Delta p\) | design fan pressure | Pa |
| \(P_{std}\) | standard motor rating | W |
| \(P_{m,min}\) | minimum motor rating | W |
| \(P_s\) | power absorbed | W |
| \(P_c\) | power on cold air at the same speed and flow | W |
| \(\dot m\) | design mass flow per fan | kg/s |
| \(\rho_g\) | gas density at the fan inlet | kg/m³ |
| \(M_g\) | molar mass of the gas | kg/kmol |
| \(p_{in}\) | absolute pressure at the fan inlet | Pa |
| \(m_g\), \(n_g\) | wet flue gas per kg of fuel, by mass and in kmol | kg/kg, kmol/kg |
| \(m_a\) | dry air per kg of fuel | kg/kg |
| \(p\) | barometric pressure | Pa |
Method and standards
Flue gas from the exact-ratio combustion balance with ASME PTC 4-2013 air, plus air in-leakage; ideal-gas density at the fan inlet; site pressure from ISO 2533; fan power as V Δp / η with the fan pressure and efficiency on the same basis (both total or both static), in the ISO 5801 form with the compressibility coefficient taken as 1, which slightly overstates the power at high fan pressures (a few per cent at 10 kPa); motor ratings IEC 60072-1. The cold-start power follows the fan laws at constant speed and volume (power in proportion to density). Default efficiency and margins are FireCAD design practice (owner, 2026-11-10).
Where it is used
- Sizing induced draught fans of balanced-draught boilers.
- Checking ID fan capacity for a fuel change, higher excess air or air heater leakage.
- Specifying fans for ESP, bag filter and scrubber retrofits, which add pressure drop.
Common mistakes
- Leaving out air heater and duct leakage from the gas flow.
- Using the design gas temperature without the higher temperature of a fouled boiler.
- Forgetting the extra draught loss of a new dust collector.
Assumptions and limits
- Gas temperature at the fan inlet is your design value; the leaking air is taken as already mixed in at that temperature.
- Fly ash is not part of the gas flow.
- The cold-start check assumes the fan reaches full speed with the dampers open on ambient air; real starts are usually made with dampers closed. The cold air is taken as dry, at the same inlet pressure as the hot design case.
- Only the mass flow carries a margin; for a fouled or aged boiler, enter the higher gas temperature yourself.
References
- ASME PTC 4-2013 (air composition)
- ISO 5801 (fan power)
- ISO 2533 (site pressure)
- IEC 60072-1 (motor ratings)
Questions and answers
How is an ID fan sized?
From the flue gas at MCR plus the air leaking in up to the fan, at the gas temperature and the pressure at the fan inlet, plus the flow margin. For 12 t/h of Indian coal at 25 % excess air with 10 % leakage at 140 °C the fan needs 43.7 m³/s; at 2.5 kPa and 80 % it absorbs 137 kW, so a 160 kW motor.
What is the cold-start check?
Started on cold air the fan moves the same volume at the same speed, but the air is denser, so it absorbs more power: 184 kW in that example, more than the motor. Start it with inlet dampers or vanes closed, use a variable speed drive, or take a larger motor.
Where does the fan pressure come from?
From the draught balance: furnace suction plus the losses of the boiler, economiser, air heater, dust collector and ducts, less the stack's natural draught.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.