Worked example
Example: Coal flue gas 60 t/h, 150 °C, 15 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flue gas mass flow | 60,000 kg/h |
| Flue gas molar mass | 30.000 kg/kmol |
| Flue gas temperature at the exit | 150.00 °C |
| Pressure at the exit (absolute) | 1.0132 bar |
| Design exit velocity | 15.000 m/s |
| Chosen inside diameter to check (0 = skip) | 0 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Required inside diameter | 1.2796 m |
| Flow area | 1.2860 m² |
| Actual flue gas volume flow | 69,445 m³/h |
| Normal flue gas volume flow (0 °C, 1 atm) | 44,828 Nm³/h |
| Flue gas density at the exit | 0.86399 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\rho_g = \frac{p\,M_g}{R\,T_g} \qquad \dot V_g = \frac{\dot m_g}{\rho_g} \qquad A = \frac{\dot V_g}{v} \qquad D = \sqrt{\frac{4A}{\pi}}\)
\(\dot V_{g,N} = \frac{\dot m_g\,V_{m,N}}{M_g} \qquad v_{sel} = \frac{4\,\dot V_g}{\pi\,D_{sel}^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | flue gas mass flow | kg/s |
| \(M_g\) | flue gas molar mass | kg/kmol |
| \(T_g\) | flue gas temperature at the exit | K |
| \(p\) | absolute pressure at the exit | Pa |
| \(v\) | design exit velocity | m/s |
| \(D_{sel}\) | chosen inside diameter to check | m |
| \(D\) | required inside diameter | m |
| \(A\) | flow area | m² |
| \(\dot V_g\) | actual flue gas volume flow | m³/s |
| \(\dot V_{g,N}\) | normal flue gas volume flow (0 °C, 101.325 kPa) | Nm³/s |
| \(\rho_g\) | flue gas density at the exit | kg/m³ |
| \(v_{sel}\) | exit velocity in the chosen diameter | m/s |
| \(R\) | universal gas constant | J/(mol·K) |
| \(V_{m,N}\) | molar volume at 0 °C, 101.325 kPa (22.414 m³/kmol) | m³/kmol |
Method and standards
Continuity for a circular duct and the ideal-gas density at the exit temperature and pressure. Normal volume with the ideal-gas molar volume at 0 °C and 101.325 kPa (CODATA 2018).
Where it is used
- First sizing of chimneys and stacks.
- Checking exit velocity for plume rise and downwash.
- Retrofits that change gas flow.
Common mistakes
- Using normal gas volume instead of actual at stack temperature.
- Choosing a low exit velocity that causes downwash.
- Ignoring part-load velocity.
Assumptions and limits
- Circular inside section; for a rectangular flue use the equivalent diameter.
- Uniform velocity over the section.
- Ideal gas; the molar mass of wet flue gas is about 30 kg/kmol for coal and oil and 27.5–28.5 kg/kmol for natural gas.
References
- Continuity equation; ideal gas (CODATA 2018 gas constant)
Questions and answers
How do I size a chimney diameter?
Divide the actual flue gas volume by the chosen exit velocity to get the area, then D = √(4A/π). 60 t/h of coal flue gas at 150 °C is 19.3 m³/s; at 15 m/s the stack needs a 1.28 m inside diameter.
Which exit velocity should I choose?
The calculator does not suggest one. The velocity comes from the plume-rise and downwash rules of your permit, the draught available and the fan design, so it is your input.
Why is the mass flow the input?
The mass flow is the same all along the gas path; the volume changes with temperature. The combustion air and flue gas calculator gives the flue gas mass flow and molar mass.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.