Worked example
Example: 180 °C gas, Y 0.10. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry flue gas flow | 100.00 t/h |
| Gas in | 180.00 °C |
| Humidity in (kg water per kg dry gas) | 0.10000 kg/kg |
| Dry gas specific heat | 1.0500 kJ/(kg·K) |
| Dry gas molar mass | 30.000 kg/kmol |
| Gas pressure (absolute) | 100.00 kPa |
| Make-up water temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas out (saturated) | 61.076 °C |
| Humidity out | 0.15924 kg/kg |
| Water evaporated | 5.9241 t/h |
Open this example in the calculator and change any input.
Formula
\(c_{p,g}T_1 + Y_1 h_v(T_1) + (Y_s - Y_1)h_l(T_w) = c_{p,g}T_s + Y_s h_v(T_s), \quad Y_s = \frac{M_w}{M_g}\frac{p_s(T_s)}{p - p_s(T_s)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Dry flue gas flow | kg/s |
| \(T_1\) | Gas in | K |
| \(Y_1\) | Humidity in (kg water per kg dry gas) | kg/kg |
| \(c_{p,g}\) | Dry gas specific heat | J/(kg·K) |
| \(M_g\) | Dry gas molar mass | kg/kmol |
| \(p\) | Gas pressure (absolute) | Pa |
| \(T_w\) | Make-up water temperature | K |
| \(T_s\) | Gas out (saturated) | K |
| \(Y_s\) | Humidity out | kg/kg |
| \(\dot m_v\) | Water evaporated | kg/s |
Method and standards
Adiabatic saturation energy balance per kg of dry gas, solved by bisection for the saturation temperature. Saturation pressure from IAPWS-IF97; the vapour enthalpy h_v is the IF97 value at 700 Pa (low partial pressure, ideal-gas behaviour) and the make-up water enthalpy h_l the IF97 liquid value at 101.325 kPa.
Where it is used
- Wet scrubber and quench design.
- Stack reheat studies.
Common mistakes
- Wet gas flow used as dry.
Assumptions and limits
- Adiabatic; ideal-gas vapour.
- One dry-gas specific heat from the inlet temperature down to saturation; the true mean over a wide range (up to 500 °C) differs by a few per cent.
- The saturation temperature is searched between 0.35 °C and the lower of the gas inlet temperature and the boiling point at the gas pressure; inputs with no solution in that range are rejected.
References
- Adiabatic saturation energy balance; saturation pressure and vapour enthalpy from IAPWS-IF97
Questions and answers
Why does the gas cool so much?
Evaporating water takes its latent heat from the gas until the gas is saturated.
Typical outlet?
Around 50–65 °C for boiler flue gas, depending on its moisture.
Water use?
The evaporated water is lost with the gas; add blowdown and droplet carry-over for make-up.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.